It is difficult to predict child HRQOL based on clinical measurements. However, parent HRQOL tends to be worse with poorer control and larger angle of deviation. Perhaps HRQOL should be routinely assessed in clinic alongside clinical measurements in order to tailor management appropriately.
PurposeTo evaluate posterior eye shape variations across a wide refractive error range using brain MRI in a multiethnic cohort.MethodsAdult subjects in the multiethnic Singapore Epidemiology of Eye Disease study were included. Spherical equivalent (SE) was measured using subjective refraction, and axial length (AL) was measured using optical biometry. MRI was performed using a 3-Tesla whole body scanner with a 32-channel head coil. The radii and asphericity based on fitting of the posterior two-thirds of the eye (240°) were calculated. The refractive error status was categorised as myopic (SE<−0.5 D) or non-myopic (SE≥−0.5 D).ResultsA total of 450 adult participants (mean age 64.2±6.5 years old) were included. Less oblate asphericity was associated with more myopic SE, longer AL and with a refractive error categorisation of myopia (p<0.001 for all). Asphericity values were less oblate in myopic compared with non-myopic eyes (p<0.001). Multivariate analysis showed that Chinese subjects had less oblate eyes than Malay and Indian subjects, especially in non-myopic eyes.ConclusionsA less oblate posterior eye shape was associated with myopic eyes. Chinese eyes have less oblate shapes than Malay and Indian eyes, especially in non-myopic eyes.
ObjectivesOphthalmology units across the UK vary widely in their adoption of electronic medical records (EMR). There is a lack of evidence to show the extent and progress of EMR adoption. The aim of this study was to capture a snapshot of the current landscape of EMR use, as a baseline for comparison in future studies.SettingAn electronic survey questionnaire was sent to all NHS ophthalmology Units in the UK.ParticipantsA total of 104 National Health Service (NHS) ophthalmology units participated in the survey, which was carried out over 6 months from December 2013 to June 2014.Primary and secondary outcome measuresRespondents were asked about technology usage pertaining to specific processes in the clinic workflow. This allowed us to determine the extent of EMR usage and details about current use or planned implementation by each unit.Results77.6% (n=104) of NHS ophthalmology units responded. 45.3% (n=48) of units were currently using an EMR and a further 26.4% (n=28) of units plan to implement EMR within 2 years. 70.8% of units with a current EMR system use Medisoft. EMR is used by all clinicians in 37.5% and by all subspecialties offered at the unit in 27.0%. In 56.3%, new clinical notes are entered into EMR only by clinicians. All imaging devices are networked to EMR in 28.3%. In 46.7%, EMR is accessible by other specialties within the same hospital. 71.1% would recommend EMR to a colleague.ConclusionsEMR has the potential to address current limitations of patient information transfer and sharing in ophthalmology. It is pleasing to see a significant proportion of units already engaging with EMR or having plans to do so in the near future. However, differing EMR systems and lack of remote access mean further optimisation of these record systems are needed to allow data transfer between units.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.