Recent years have witnessed rapid developments in organic-inorganic hybrid perovskites, among which 2D Ruddlesden-Popper (RP) perovskites stand out due to their outstanding ambient stability. In photodetector applications, 2D RP perovskites are mostly limited to lateral device configuration because of their preferred in-plane charge transportation within quantum well structures. In this work, the low-temperature solution construction of 2D RP perovskite-based photodiodes in vertical device architecture is demonstrated. The paradigm phenylethylamine (PEA) spacer cation-based 2D perovskites are fabricated and optimized by exploiting a combination of a NH Cl additive and dimethyl sulfoxide solvent (DMSO) solvent. They show increased crystallinity, extended photoluminescence lifetimes, and importantly a generation of 3D phases embedded within 2D perovskites, which efficiently promotes charge transfer. As a result, the photodetectors exhibit a high on/off ratio up to 2 × 10 , a large photocurrent of 0.34 mA cm , and rapid rise (5.8 ms) and decay time (4.6 ms). Of critical importance is the outstanding film/device stabilities demonstrated by storage in air (at 25 °C with 60% relative humidity) for 15 days as well as under UV illumination for 1.5 h and after 1500 bending cycles on flexible substrate.
A new interconnect parasitic extraction flow considering geometry-related variation has been proposed in this letter. The 42 interconnect capacitance loads were fabricated by 55-nm process technology and measured to characterize geometric variation. According to the new extraction flow, interconnect technology file (ITF) has been optimized and established. As a result, both extracted error by layout parasitic extraction tool and simulated error by field solver have been improved obviously with this optimized ITF. Meanwhile, an on-chip interconnect test technique with nonoverlapping signal generation circuitry based on charge-induced-injection error-free charge-based capacitance measurement has been designed in this letter to simplify the test procedure.Index Terms-Geometric-related variation, interconnect parasitic extraction, charge-induced-injection error-free charge-based capacitance measurement (CIEF CBCM), non-overlapping signal generation circuitry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.