Dynamic OCT coupled with high-resolution video demonstrated that soft contact lens movement and image-corrected ocular surface indentation were influenced by both lens edge design and midperipheral lens shape profiles.
Purpose. To examine the influence of positional misalignments on intraocular pressure (IOP) measurement with a rebound tonometer. Methods. Using the iCare rebound tonometer, IOP readings were taken from the right eye of 36 healthy subjects at the central corneal apex (CC) and compared to IOP measures using the Goldmann applanation tonometer (GAT). Using a bespoke rig, iCare IOP readings were also taken 2 mm laterally from CC, both nasally and temporally, along with angular deviations of 5 and 10 degrees, both nasally and temporally to the visual axis. Results. Mean IOP ± SD, as measured by GAT, was 14.7 ± 2.5 mmHg versus iCare tonometer readings of 17.4 ± 3.6 mmHg at CC, representing an iCare IOP overestimation of 2.7 ± 2.8 mmHg (P < 0.001), which increased at higher average IOPs. IOP at CC using the iCare tonometer was not significantly different to values at lateral displacements. IOP was marginally underestimated with angular deviation of the probe but only reaching significance at 10 degrees nasally. Conclusions. As shown previously, the iCare tonometer overestimates IOP compared to GAT. However, IOP measurement in normal, healthy subjects using the iCare rebound tonometer appears insensitive to misalignments. An IOP underestimation of <1 mmHg with the probe deviated 10 degrees nasally reached statistical but not clinical significance levels.
The OCT based instrument assessed in this study is able to match and improve on the JCF instrument for the measurement of total diameter, back optic zone radius and centre thickness for soft contact lenses in temperature controlled saline.
The key determinants of the range of clear focus in pre-presbyopes and their relative contributions to the difference between subjective range of focus and objective accommodation assessments have not been previously quantified. Fifty participants (aged 33.0 ± 6.4 years) underwent simultaneous monocular subjective (visual acuity measured with an electronic test-chart) and objective (dynamic accommodation measured with an Aston open-field aberrometer) defocus curve testing for lenses between +2.00 to −10.00 DS in +0.50 DS steps in a randomized order. Pupil diameter and ocular aberrations (converted to visual metrics normalized for pupil size) at each level of blur were measured. The difference between objective range over which the power of the crystalline lens changes and the subjective range of clear focus was quantified and the results modelled using pupil size, refractive error, tolerance to blur, and ocular aberrations. The subjective range of clear focus was principally accounted for by age (46.4%) and pupil size (19.3%). The objectively assessed accommodative range was also principally accounted for by age (27.6%) and pupil size (15.4%). Over one-quarter (26.0%) of the difference between objective accommodation and subjective range of clear focus was accounted for by age (14.0%) and spherical aberration at maximum accommodation (12.0%). There was no significant change in the objective accommodative response (F = 1.426, p = 0.229) or pupil size (F = 0.799, p = 0.554) of participants for levels of defocus above their amplitude of accommodation. Pre-presbyopes benefit from an increased subjective range of clear vision beyond their objective accommodation due in part to neural factors, resulting in a measured depth-of-focus of, on average, 1.0 D.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.