The aim of this study was to determine the effect of spinal manipulation therapy (SMT) force magnitude and force duration on the spinal stiffness of a feline preparation. A mechanical device performed simulated SMTs at the L6 spinous process in 22 anesthetised felines. Subjects were divided into four groups. Two groups (no preload, preload) received SMT having maximal displacements of 1.0mm, 2.0mm and 3.0mm of total displacement (displacement control). In two other groups (preload, no preload), SMTs were applied with maximal loads of 25%, 55% and 85% body weight (force control). Each of the SMTs were applied in order of increasing displacement or force amplitudes, at increasing durations ranging from 25 to 250 ms. Spinal stiffness was quantified by applying an indentation load to external surface of the back. Linear mixed effects models were fit for post-SMT stiffness variables. When SMT was applied under displacement control with and without a preceding preload, a significant interactive effect occurred between force magnitude and force duration (p≤0.05) for some of the stiffness variables. The findings from this experiment demonstrate that spinal stiffness in a feline model was affected by the interaction of the force amplitude and force duration parameters but the exact nature of this interaction remains unclear. This study provides guidance for further investigation given other SMT parameters not tested here may facilitate the ability of SMT to alter spinal stiffness.
This study demonstrates that lumbar function assessed by self-reported and objective measures does not worsen when nonrigid, inelastic bracing is used for short periods of time for those with, or without, back pain. These data add to the existing literature that suggests short-term use of nonrigid, inelastic bracing for acute LBP does not decrease spinal function when measured separately with subjective or objective tools.
Structural health monitoring (SHM) is an engineering technique used to identify mechanical abnormalities not readily apparent through other means. Recently, SHM has been adapted for use in biological systems, but its invasive nature limits its clinical application. As such, the purpose of this project was to determine if a non-invasive form of SHM could identify structural alterations in the spines of living human subjects. Lumbar spines of 10 twin pairs were visualized by magnetic resonance imaging then assessed by a blinded radiologist to determine whether twin pairs were structurally concordant or discordant. Vibration was then applied to each subject’s spine and the resulting response recorded from sensors overlying lumbar spinous processes. The peak frequency, area under the curve and the root mean square were computed from the frequency response function of each sensor. Statistical analysis demonstrated that in twins whose structural appearance was discordant, peak frequency was significantly different between twin pairs while in concordant twins, no outcomes were significantly different. From these results, we conclude that structural changes within the spine can alter its vibration response. As such, further investigation of SHM to identify spinal abnormalities in larger human populations is warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.