The effect of surface treatment of titanium on hydrogen absorption was investigated.Surface treated titanium specimens prepared by polishing, anodizing and air oxidizing were immersed in 0.5-6%HCl solutions at the temperature range of 70C to 250C. After immersion, the weight loss, hydrogen content and oxide film thickness of three specimens were measured. As a result, it became clear that anodizing did not reduce hydrogen absorption of titanium because titanium oxide film formed by anodizing had dissolved away in dilute HCl solutions for short time but air oxidizing specimen was stable in this solution for long time and so prevented to hydrogen absorption of titanium.These results of laboratory tests corresponded to the results of field tests conducted in hot molten urea and reducing acid solution at high temperature.
Hydrogen absorption of Ti-Pd alloys in deaerated and aerated hydrochloric acid solutions where Ti-Pd alloys are in the passive state were compared with that of pure titanium. In particular, the role of palladium in the hydrogen absorption of Ti-Pd alloy was discussed. The results obtained are as follows;
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.