The water equivalency of five "water-equivalent" solid phantom materials was evaluated in terms of output calibration and energy characterization over a range of energies for both photon (Co-60 to 24 MV) and electron (6-20 MeV) beams. Evaluations compared absorbed doses calculated from ionization measurements using the same dosimeter in the solid phantom materials and in natural water (H2O). Ionization measurements were taken at various calibration depths. The Radiological Physics Center's standard dosimetry system, a Farmer-type ion chamber in a water phantom, was used. Complying with the TG-21 calibration protocol, absorbed doses were calculated using eight measurement and calculational techniques for photons and five for electrons. Results of repeat measurements taken over a period of 2 1/2 years were reproducible to within a +/- 0.3% spread. Results showed that various combinations of measurement techniques and solid phantom materials caused a spread of 3%-4% in the calculation of dose relative to the dose determined from measurements in water for all beam energies on both modalities. An energy dependence of the dose ratios was observed for both photons and electrons.
Cooperative clinical trial group protocols frequently require off-axis point dose calculations. The Radiological Physics Center uses the calculative technique developed by Hanson et al. [Med. Phys. 7, 145-146 (1980); 7, 147-150 (1980)] to verify these calculations. In order to correct for off-axis energy changes, this technique requires off-axis half-value layer data, HVL, as a function of off-axis ray angle for the specific beam. This paper presents a formulism based on HVL mesurements on a limited number of therapy beams, which allows the calculation of an off-axis energy-correction factor for any clinical photon beam created by a linear accelerator using conventional flattening filters.
Dosimetric accuracies at low monitor units are evaluated for linear accelerators from various manufacturers. A large error is observed in the majority of the accelerators. The error can be positive or negative. Although the error can exceed 20% for the first few monitor units, it is usually less than 5% when more than 10 monitor units are delivered. When low doses are required proper precautions should be taken for dosimetric accuracy including the beam energy, beam flatness and dose per monitor unit.
A key component of the Radiological Physics Center's (RPC) on-site dosimetry review visits are photon beam calibrations for which determination of the energy of the x ray is a key element. The ratio of ionizations, TPR20/TPR10, for a 10 cm x 10 cm field at depths of 20 and 10 cm for a constant SCD is used as a quantitative measure of beam quality in the Task Group 21 protocol. The RPC has measured both TPR20/TPR10 and the corresponding ratio of percent depth dose (D20/D10) at a constant SSD for 685 photon beams (4-25 MV) for most makes and models if accelerators. A strong correlation between TPR20/TPR10 and D20/D10 is presented which allows the determination of the TPR ratio from the measurement of the ratio of percent depth doses. An analysis of the uncertainty introduced in the TG-21 factors (L/rho, Pwall, Prepl) caused by the spread in the measured data and translated into the determination of the TPR ratio results in an insignificant error (< 0.3%). This empirical relationship provides an alternate technique for quantifying the beam quality defined in the TG-21 protocol without surrendering any loss of precision in output calibration. This technique may be found by those who calibrate at a fixed SSD to be an easier and quicker method.
The device developed by the authors and described here enables the user to measure the depth from the water surface to the point of measurement for a cylindrical ion chamber with a waterproof plastic cap in a water phantom, free of surface-tension error with a high precision. The device seeks vertical orientation and provides the convenience of hands-free operation. The measurement process is simple and quick with a precision of 0.1 mm. (The device is currently available as a 'water phantom depth gauge' from Nuclear Associates, Division of Victoreen Inc., Clare Place, NY, USA.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.