This paper reports vacuum data for nickel-tin transient liquid phase (TLP) wafer bonding. Two wafers, one with a titanium getter and another with Pirani vacuum sensors, were bonded for 1.5 hours at 300 °C. Initial pressures were as low as 200 mTorr and have remained stable for half a month. After several days, some of the packages were heated to 400 °C for 10 minutes to test the thermal integrity of the TLP bond. The bond remained intact; the pressure inside each of the cavities dropped by further activating the getter and has remained steady at the new lower pressure for several weeks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.