Aromatic amines (AA) are carcinogenic compounds that can enter the human body through many sources, one of the most important being tobacco smoke. They are excreted with the urine, from which they can be extracted and measured. To that end, hollow fiber-liquid-phase microextraction (HF-LPME) and parallel artificial liquid membrane extraction (PALME) were optimized for the analysis of representative aromatic amines, as alternatives to liquid–liquid extraction (LLE). Relevant extraction parameters, namely organic solvent, extraction time, agitation speed, and acceptor solution pH, were studied, and the two optimized techniques—HF-LPME: dihexyl ether, 45 min, 250 rpm, and pH 1; PALME: undecane, 20 min, 250 rpm and pH 1—were compared. Comparison of the optimized methods showed that significantly higher recoveries could be obtained with PALME than with HF-LPME. Therefore, PALME was further validated. The results were successful for nine different AA, with regression coefficients (R2) of at least 0.991, limits of detection (LOD) of 45–75 ng/L, and repeatability and peak area relative standard deviations (RSD) below 20%. Furthermore, two urine samples from smokers were measured as proof of concept, and 2-methylaniline was successfully quantified in one of them. These results show that PALME is a great green alternative to LLE. Not only does it use much smaller volumes of toxic organic solvents, and sample—enabling the study of samples with limited available volumes—but it is also less time consuming and labor intensive, and it can be automated.
Graphical Abstract
Coffee is typically brewed by extracting roasted and milled beans with hot water, but alternative methods such as cold brewing became increasingly popular over the past years. Cold-brewed coffee is attributed to health benefits, fewer acids, and bitter substances. But the preparation of cold brew typically needs several hours or even days. To create a cold-brew coffee within a few minutes, we present an approach in which an ultrashort-pulsed laser system is applied at the brewing entity without heating the powder suspension in water, efficiently extracting caffeine and aromatic substances from the powder. Already 3 min irradiation at room temperature leads to a caffeine concentration of 25 mg caffeine per 100 ml, comparable to the concentrations achieved by traditional hot brewing methods but comes without heating the suspension. Furthermore, the liquid phase’s alkaloid content, analyzed by reversed-phase liquid chromatography coupled to high-resolution mass spectrometry, is dominated by caffeine and trigonelline and is comparable to traditional cold-brewed coffee rather than hot-brewed coffee. Furthermore, analyzing the head-space of the prepared coffee variants, using in-tube extraction dynamic head-space followed by gas chromatography coupled to mass spectrometry, gives evidence that the lack of heating leads to the preservation of more (semi-)volatile substances like pyridine, which provide cold-brew coffee its unique taste. This pioneering study may give the impetus to investigate further the possibility of cold-brewing coffee, accelerated by more than one order of magnitude, using ultrafast laser systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.