Within the framework of the European Commission's Measurements and Testing Programme (BCR) a project has been undertaken to develop shellfish reference materials for Paralytic Shellfish Poisons (PSP). In a preliminary phase of the project, an intercomparison study of methods was undertaken. In this exercise 18 laboratories were asked to analyse solutions of saxitoxin and PSP-containing shellfish extracts with a method of their choice. The study revealed that: all the methods considered (four HPLC methods, one ELISA method) were in principle adequate for the quantification of saxitoxin in solution in the absence of interfering substances (Coefficient of variation (CV) 33% at a concentration of 0.5 microgram/ml); three of the HPLC methods used were able to quantify saxitoxin in PSP-positive mussel extract, the fourth method gave significant overestimation; the CV of all HPLC results was 53% at a mean saxitoxin mass fraction of 2.06 mg/kg mussel meat, the recoveries varied from 59-173%; and the ELISA method grossly overestimated the saxitoxin content in mussel extract, probably due to cross reactions of the antibodies with other PSP. The feasibility of preparing a homogeneous batch of ampouled mussel extracts (CV 3.5% at a saxitoxin concentration of approximately 1.5 mg/kg shellfish), sufficiently stable for at least 4 months storage both at 4 degrees C and approximately 20 degrees C, was demonstrated. The performance of the different methods for the analysis of PSP other than saxitoxin has not yet been evaluated, due to the current lack of PSP standards. Some of the problems observed in the intercomparison study were partly due to the nature of the chromatographic columns used, the composition of the HPLC mobile phase (pH, ion strength), non-optimal conditions for derivatization and matrix interference. Following the outcome of this study, a three year multistage project involving 15-20 European laboratories has been initiated, aimed at improving the accuracy and comparability of PSP measurements as well as preparing reference materials for PSP.
It aims to provide evidence-based scientific support to the European policy-making process. The scientific output expressed does not imply a policy position of the European Commission. Neither the European Commission nor any person acting on behalf of the Commission is responsible for the use which might be made of this publication.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.