Volume overload is a predictor of mortality in dialysis patients. However, the fluid status of patients with chronic kidney disease (CKD) but not yet on dialysis has not been accurately characterized. We used the Body Composition Monitor, a multifrequency bioimpedance device, to measure the level of overhydration in CKD patients, focusing on the association between overhydration and cardiovascular disease risk factors. Overhydration was the difference between the amount of extracellular water measured by the Body Composition Monitor and the amount of water predicted under healthy euvolemic conditions. Volume overload was defined as an overhydration value at and above the 90th percentile for the normal population. Of the 338 patients with stages 3-5 CKD, only 48% were euvolemic. Patients with volume overload were found to use significantly more antihypertensive medications and diuretics but had higher systolic blood pressures and an increased arterial stiffness than patients without volume overload. In a multivariate analysis, male sex, diabetes, pre-existing cardiovascular disease, systolic blood pressure, serum albumin, TNF-α, and proteinuria were independently all associated with overhydration. Thus, volume overload is strongly associated with both traditional and novel risk factors for cardiovascular disease. Bioimpedance devices may aid in clinical assessment by helping to identify a high-risk group with volume overload among stages 3-5 CKD patients.
SummaryBackground and objectives Relatively little is known about the long-term outcomes of different histologic types of primary glomerulonephritis in Asian populations.Design, setting, participants, & measurements From 1993 to 2006, 987 patients undergoing renal biopsy were studied, and 580 patients (mean age=44.4 years, male=58.5%) with the four most common forms of glomerulonephritis (membranous nephropathy, focal and segmental glomerulosclerosis, IgA nephropathy, and minimal change disease) were selected for analysis. Median follow-up period was 5.9 (interquartile range=5.7) years.Results The focal and segmental glomerulosclerosis group displayed the highest incidence of ESRD (25.8%) and the fastest decline of estimated GFR (4.6 ml/min per 1.73 m 2 per year). The IgA nephropathy group also had a higher rate of ESRD than the membranous nephropathy patients (19.2% versus 4.3%, P,0.001). In contrast, the membranous nephropathy group exhibited an overall death rate similar to the focal and segmental glomerulosclerosis group (17.2% versus 14.4%) but higher than the IgA nephropathy and minimal change disease patients (4.6% and 3.7%, respectively, P,0.001). The most powerful predictor for ESRD was focal and segmental glomerulosclerosis, whereas the strongest predictor for all-cause mortality was membranous nephropathy with higher proteinuria. Protectors against ESRD included male sex and higher hemoglobin.Conclusions Most predictors for ESRD and overall mortality found in this ethnic Chinese cohort were similar to other studies. However, some risk factors linked with distinct glomerular pathologies displayed differential clinical outcomes.
BackgroundSymptoms of heart failure with preserved left ventricular systolic function are common among patients undergoing peritoneal dialysis (PD). Epicardial fat (EpF) is an ectopic fat depot with possible paracrine or mechanical effects on myocardial function. The aim of our current study is to assess the association between EpF and Left ventricular diastolic dysfunction (LVDD) in patients undergoing PD and to clarify the relationships among EpF, inflammation, and LVDD in this population.MethodsThis was a cross-sectional study of 149 patients with preserved left ventricular systolic function who were undergoing PD. LVDD was diagnosed (according to the European Society of Cardiology guidelines) and EpF thickness measured by echocardiography. The patients without LVDD were used as controls. The serum inflammatory biomarker high-sensitivity C-reactive protein (hsCRP) was measured. The location and amount of adipose tissue were assessed by computed tomography (CT) at the level of the fourth lumbar vertebra.ResultsSubjects with LVDD had higher levels of hsCRP, more visceral and peritoneal fat, and thicker EpF (all p < 0.001) than controls. Visceral adipose tissue, hsCRP, and EpF all correlated significantly (p < 0.05) with LVDD. Multivariate regression analysis rendered the relationship between visceral adipose tissue and LVDD insignificant, whereas EpF was the most powerful determinant of LVDD (odds ratio = 2.41, 95% confidence interval = 1.43–4.08, p < 0.01). EpF thickness also correlated significantly with the ratio of transmitral Doppler early filling velocity to tissue Doppler early diastolic mitral annular velocity (E/e’; r = 0.27, p < 0.01).ConclusionEpF thickness is significantly independently associated with LVDD in patients undergoing PD and may be involved in its pathogenesis.
The ultrafast metal-gate silicon quantum-dot (Si-QD) nonvolatile memory (NVM) with program/ erase speed of 1 ls under low operating voltages of 6 7 V is achieved by thin tunneling oxide, in situ Si-QD-embedded dielectrics, and metal gate. Selective source/drain activation by green nanosecond laser spike annealing, due to metal-gate as light-blocking layer, responds to low thermal damage on gate structures and, therefore, suppresses re-crystallization/deformation/ diffusion of embedded Si-QDs. Accordingly, it greatly sustains efficient charge trapping/de-trapping in numerous deep charge-trapping sites in discrete Si-QDs. Such a gate nanostructure also ensures excellent endurance and retention in the microsecond-operation Si-QD NVM. V
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.