Paravalvular leaks without overt endocarditis had latency periods of up to 12 years, and pannus formation was observed 20 years after surgery. Early and late clinical results after surgery for mechanical valve dysfunction were excellent.
ObjectivePatient-prosthesis mismatch (PPM) may affect clinical outcomes in patients with aortic valve replacement (AVR). We retrospectively examined the PPM in patients with isolated AVR in the Japan Adult Cardiovascular Surgery Database (JACVSD).MethodsWe examined all patients with isolated AVR between January 1, 2008 and December 31, 2009. The JACVSD data collection form has a total of 255 variables. We defined PPM as an effective orifice area index of ≤0.85 m2/cm2.ResultsPPM was observed in 306 of 3,609 cases analyzed, PPM rate was 8.5 %. Body surface area was larger and body mass index was higher in the PPM group than the non-PPM group (P < 0.001). Patients with PPM were older (P = 0.001) and had a higher prevalence of diabetes (P = 0.004), dyslipidemia (P < 0.001), hypertension (P < 0.001), cerebrovascular disease (P = 0.031), old myocardial infarction (P = 0.006), previous percutaneous coronary artery intervention (P = 0.001), coronary artery disease (P = 0.018), and aortic valve stenosis (P < 0.001). Perioperative blood transfusion (P < 0.001) and dialysis (P = 0.005) were more frequent in the PPM group. Postoperative ventilation (P = 0.004) and intensive care unit stay (P = 0.004) were significantly longer in the PPM group.ConclusionsAge, aortic valve stenosis, dyslipidemia, hypertension, old myocardial infarction, previous percutaneous coronary artery intervention, diabetes mellitus, cerebrovascular disease, and high body mass index were the risk factors for PPM. PPM was not an independent risk factor for short-term mortality.
Bacground: We have previously reported mid-term results of a study, which ended in January 2000, on the Bicarbon valve. The study concluded that the valve showed excellent clinical results, associated with a low incidence of valve-related complications. In the present study, the same patients were prospectively followed for an additional 5 years.Methods: Forty-four patients had aortic valve replacement (AVR), 48 had mitral valve replacement (MVR), and 13 had both aortic and mitral valve replacement (DVR). The mean age of the 105 patients was 61.2 ± 11.3 years. The mean follow-up was 6.1 ± 1.9 years with a cumulative followup of 616 patient-years.Results: There were 5 early deaths (4.7%: 4 in the AVR group and 1 in the MVR group) and 21 late deaths (3.4%/patient-year: 5 valve related deaths and 16 valve unrelated deaths). Survival at 8 years was 75.2 ± 7.0% in the AVR group, 76.6 ± 6.2% in the MVR group, and 55.4 ± 16.1% in the DVR group. The linearized incidence of thrombo-embolic complications, hemorrhagic complications, and paravalvular leaks in all patients was 0.65 ± 1.48%, 0.81 ± 1.69%, and 0.16 ± 0.54%/patient-year respectively. No other complications were observed.
Conclusion:The Bicarbon prosthetic heart valve has shown excellent long-term clinical results, associated with a low incidence of valve-related complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.