Purpose: This study evaluated the contrast-to-noise ratio (CNR), spatial resolution, and subjective quality of dual imaging plates (DIP) intraoral radiography. Methods:The DIP and conventional single IP (CSIP) methods both used YCR DT-1 imaging plates (Yoshida Co.). The DIP, comprising a front IP (FIP) and back IP (BIP), was constructed. DIP images were synthesized from the FIP and BIP images. An aluminum step phantom was used to measure the CNR. A line pair gauge was used to measure the spatial imaging resolution. A phantom comprising a porcine mandible embedded in acrylic resin was used for subjective evaluation. Results:The CNR of the DIP image was 32% higher than that of the FIP image. The spatial resolution achieved using the FIP, DIP, and CSIP was highly comparable except above 4 line pairs/mm, where that of the CSIP was highest. In subjective evaluation, the noise in the DIP images was significantly lower than in those obtained using the FIP and CSIP. Conclusion:The CNR of the DIP was higher than that of the FIP. The decrease in spatial resolution of the DIP was limited. The subjective image quality of the DIP was higher than that of the FIP.
Purpose: Circadian rhythm is associated with the pathogenesis of systemic disease and bone mineral metabolism. This study aimed to radiographically evaluate morphological characteristics of the interalveolar septum in circadian rhythm deficient animals. Methods: Heads of 10 brain and muscle arnt-like protein-1 (BMAL1)knockout (KO) mice and 10 wild-type mice sacrificed at 36 weeks were imaged using micro-computed tomography. The mean depth from the cementoenamel junction to the alveolar ridge (virtual bone sounding: VBS) of the interalveolar septum between the first and second molars, and the bone mineral density (BMD) of the interalveolar septum and the mandibular inferior cortex region were calculated. Tooth diameter was also measured. Results: The VBS of the interalveolar septum in the BMAL1-KO mice was significantly deeper than that in wild-type mice. The BMD in the BMAL1-KO mice was significantly lower than in the wild-type mice in both regions. No significant difference was observed in tooth diameter between BMAL1-KO and wild-type mice. Conclusion:These results suggest that low BMD in the interalveolar septum accelerates bone resorption in the interalveolar septum in BMAL1-KO mice. Keywords; BMAL1, bone mineral density, circadian rhythm, periodontitis Micro-computed tomography (micro-CT)Micro-CT examination was performed using the R_mCT system (Rigaku, Tokyo, Japan) for all subjects. Imaging conditions were as follows: tube voltage 90 kV, tube current 200 μA, exposure time 2 m, voxel size 20 × 20 × 20 μm 3 , matrix size 480 × 480 × 480. The center of x, y and z axis of the FOV was set at the center of the mandible at molar region,
The present study used an aluminum phantom to calculate accurate vertical magnification values around the mental foramen on panoramic radiography (PR) and compared corrected PR (Cor-PR) thickness measurements of the aluminum phantom and mandibular cortical width (MCW) of the human head with cone-beam computed tomography (CBCT) measurements at two fields of view (FOVs). The calculated vertical magnification value for PR around the mental foramen was 1.37. Measurements of the aluminum phantom significantly differed between Cor-PR and CBCT with an FOV of 100 mm and between CBCT with FOVs of 40 and 100 mm; however, MCW measurements did not significantly differ among the three methods. There was a very strong correlation between Cor-PR and CBCT with an FOV of 40 mm and between CBCT with FOVs of 40 mm and 100 mm, and intraobserver and interobserver agreement was good-to-excellent for all methods. These results suggest that Cor-PR and CBCT with small and large FOVs are acceptable for measuring MCW.
Purpose:The dual imaging plate (DIP) method, which synthesizes intraoral radiographs from a front imaging plate (FIP) and a back imaging plate (BIP), produces adequate image quality and allows the radiation dose to be reduced. However, there are slight errors in superimposition and alignment between the FIP and BIP. The aim of this study was to establish positional correction in the DIP method and evaluate the effect. Methods: Six sets of two imaging plates were used for imaging a mesh plate and a porcine mandible phantom. Subtraction images between FIP and BIP images were synthesized in four steps: correcting horizontal and vertical direction, rotation, enlargement ratio, and enlargement ratio into 12 blocks. Variance of the pixel value on the subtraction images at each step was compared to evaluate the alignment of FIP and BIP images. Results: The variance of the pixel values in the subtraction images was gradually and significantly decreased by each step of image processing (P < 0.01), indicating that the degree of alignment of FIP and BIP images improved during the image processing. Conclusion:The present study revealed that it is possible to synthesize more precise DIP images using an additional four-step image processing technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.