There is no perfect method to test and evaluate electromagnetic shielding (EMS) clothing up to now. The main reason is that the influence laws of the emission source parameters and the test position on the shielding effectiveness (SE) of the EMS clothing has not been clarified. In this paper, the SE of the EMS clothing is tested using a semi anechoic chamber in the frequency range of 1–18 GHz. The variation of the SE of the clothing is explored when the emission source parameters and the test positions are different. It is found that the SE of the EMS clothing decreases obviously with the increase of the testing distance, and the decline degrees are different with different frequencies. The decline trend slows down and approaches stability as the distance increases to a certain extent. The influence of the emission source angle on the SE is closely related to the frequency and positive or negative effects are produced at different frequency points. The SE are low when the test points are in the leakage areas with seams and openings, and the SE are high in the normal area. Under certain conditions, the measured SE of the clothing is close to zero or even less than zero. That is, a dangerous frequency point is formed. The mechanism of the above-mentioned laws is analyzed, and a new multi-index composite evaluation method is proposed to scientifically evaluate the EMS clothing based on the comprehensive consideration of the influencing factors. This research has great significance to promote the scientific test, evaluation and relevant standard formulation of the EMS clothing, and provides a reference role for the design and production of the EMS clothing.
Electromagnetic shielding (EMS) clothing is mainly studied for its shielding effectiveness (SE) through practical testing at present, which has many problems such as large experimental error and time and labor consumption. This paper proposes a method for constructing a simulation model of EMS clothing based on feature section replacement. Firstly, a human body model based on an elliptical truncated cone is established. A feature section of the key parts is built according to the morphological characteristics of the human body. Then a clothing structure model is established by replacing the corresponding sections in the elliptical truncated cone model with these feature sections. A digital description method for the model is given. The finite integral method is selected to calculate the SE of each test part when the clothing is completely closed, and the clothing contains holes and seams. By comparison with the measured value, it is concluded that the results of the constructed simulation model are in good agreement with the measured values. This paper establishes a new method to study the SE of EMS clothing, which provides a new approach for the design, production, evaluation and related research of EMS clothing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.