SUMMARY:The objective of this study was to design custom-made prosthesis in a certain population, the morphometry needs to be measured. The results of this study were expected to provide basic data to design the ideal size of the total knee arthoplasty prosthesis for Indonesian population. This was an anthropometric study conducted on 100 healthy Indonesian population based on Computer Tomographic (CT) imaging on the distal femur resected surface. The parameters being used were Femoral Medio Lateral (fML) length, Femoral Antero Posterior (fAP) length, Femoral Medial Antero Posterior (fMAP) length, Femoral Lateral Antero Posterior (fLAP) length, and Femoral Aspect Ratio (FR). We found that the mean fAP and fML were 54.60±5.71 and 65.98±6.51, respectively. The morphometry of the distal femur were significantly different between male and female (male have larger build), however one of parameters showed different result: fLAP. This study showed that Indonesian people have smaller build compared with their Western counterpart. The proposed dimensions can be used as the basic data to design the ideal size of the custom-made knee arthoplasty prosthesis for Indonesian population.
The incidence of Deep Vein Thrombosis (DVT) is high in orthopaedic cases, associated with morbidity and mortality. This study was done to evaluate the incidence of DVT and factors that contributed to DVT in elderly patients with proximal femur fracture who underwent surgery. Patients 60 years of age and older with proximal femur fracture who underwent surgery were enrolled into this study. Daily observation of the clinical signs of DVT was done post operatively until the subjects were discharged from the hospital. D-Dimer test and contrast venography were carried out on Day 2 and between Days 4 and 7 after surgery. Results were interpreted as normal and obstruction. There were 42 eligible patients, 18 of them (42.86 %) were diagnosed with DVT. We found that positive D-Dimer test (1.40), longer duration of surgery (1.86), and presence of clinical symptoms (1.09) increased the risk of the occurence of thrombosis although not statistically significant. There were four DVT patients who passed away within 4 months after surgery due to complication from DVT. The incidence of DVT in elderly with proximal femur fracture underwent surgery was relatively high (42.86 %) with the mortality rate was 22%.
S. Epidermidis is among the most frequently isolated microorganisms found in -infection related to implanted devices and the formation of biofilm will be more resistant compared to the planktonic form. This study was carried out to determine the effect of coating on stainless steel orthopaedic implants surfaces with cinnamon oil and chitosan as bioadhesive to prevent biofilms formation of S. Epidermidis.The rod shaped stainless steel 316 L orthopaedic implant with 5 mm diameters was coated 2 times using a mixture of cinnamon oil and chitosan 3% and 2% respectively with serial concentration of cinnamon from 0.125% to 2%. The coated implants were then put into tubes that contained bacterial suspension and incubated. Subsequently, the implants were washed with PBS solution followed by MTT soulution and isopropanol acid solution. that related to biofilm formation. The results were expressed in numbers which represents the absorbance level at ELISA readings on 575 nm (A575) wavelength.The stainless steel implant coated with chitosan and cinnamon oil 2% and 1% has lower absorbance level compared with the absorbance level of S.Epidermidis biofilm only. This study showed that mixture of cinnamon oil and chitosan coated on the surface of stainless steel orthopaedic implant has an effect against S.Epidermidis biofilm formation with the minimum cinnamon oil concentration of 1%.
Highlights Complex injury and unique anatomic relationships at the sacropelvic region. Use of modified approach to access the fracture site of the sacrum where dural tear is common. No complications after surgery. Alternative treatments for managing complex pelvic and sacral fractures Denis type 2.
SUMMARY:To design custom-made prosthesis in a certain population, the morphometry needs to be measured. The results of this study were expected to provide basic data to design the ideal size of the total hip arthoplasty prosthesis for Indonesian population. This was an anthropometric study conducted on sex matched 100 healthy Indonesian mongoloid race subjects based on Computer Tomographic (CT) imaging on the proximal femur. The parameters being used in this study were Femoral Head Offset (FHO), Femoral Head Position (FHP), Femoral Head Diameter (FHD), Neck-Shaft Angle (NSA), Anteroposterior Width (APW) and Mediolateral Width at 3 different locations, and Canal Flare Index (CFI). This study showed that Indonesian has smaller proximal femur morphometry as compared to Western population. The mean value of all parameters in male were larger than female. Moreover, FHO and FHP showed significant difference among male and female indicating the location of male femoral head center lies superiorly as compared to female. The dimension of femoral canal was found to be mediolaterally oval, 1.43, 1.28, and 1,34, respectively, in 3 different cutting (20 mm above and 40 mm below lesser trochanter, and isthmus). CFI of Indonesian was classified to be stovepipe femoral canal (2.99) that is the suggestion to use cemented femoral stem. This study showed that Indonesian proximal femur dimension has smaller build compared with Western counterpart. The proposed dimensions can be used as the basic data to design the ideal size of the femoral stem for Indonesian population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.