2018
DOI: 10.3390/s18061891
|View full text |Cite
|
Sign up to set email alerts
|

A Microelectrode Array with Reproducible Performance Shows Loss of Consistency Following Functionalization with a Self-Assembled 6-Mercapto-1-hexanol Layer

Abstract: For analytical applications involving label-free biosensors and multiple measurements, i.e., across an electrode array, it is essential to develop complete sensor systems capable of functionalization and of producing highly consistent responses. To achieve this, a multi-microelectrode device bearing twenty-four equivalent 50 µm diameter Pt disc microelectrodes was designed in an integrated 3-electrode system configuration and then fabricated. Cyclic voltammetry and electrochemical impedance spectroscopy were u… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 35 publications
1
4
0
Order By: Relevance
“…The capture antibody, immobilized through an organic linker at the Au disc electrode's surface, permits detection by increasing charge transfer resistance (R ct ). Contrary to the macro-electrode's direct relation with R ct [126,132], it was found to decrease due to an increase in effective surface area, and the linear response of the current was consistent with the results reported in [130,133,134]. In this study, the contribution of nonlinear resistance (R nl ) due to a steady current represented by R nl was also decreased to 14%.…”
Section: Electrode Interfacesupporting
confidence: 91%
See 1 more Smart Citation
“…The capture antibody, immobilized through an organic linker at the Au disc electrode's surface, permits detection by increasing charge transfer resistance (R ct ). Contrary to the macro-electrode's direct relation with R ct [126,132], it was found to decrease due to an increase in effective surface area, and the linear response of the current was consistent with the results reported in [130,133,134]. In this study, the contribution of nonlinear resistance (R nl ) due to a steady current represented by R nl was also decreased to 14%.…”
Section: Electrode Interfacesupporting
confidence: 91%
“…An array of eight gold disc-shaped microelectrodes was engraved on a silicon needle with an objective of real-time in-situ monitoring of IL-6 [100] ( Figure 4A). This approach was envisioned following the development of a robust microelectrode-based electrochemical sensing platform for chemical and DNA sensing applications [124][125][126][127]. Figure 3a shows the equivalent circuit formed at the electrode-electrolyte interface.…”
Section: Electrode Interfacementioning
confidence: 99%
“…This made it possible to perform EIS measurements at OCP with theoretically equal amounts of oxidized and reduced species present before imposing the AC excitation signal. This is an approach that has been used by ourselves, , and many others previously. CV experiments were conducted between −0.4 and 0.6 V with a step of 0.01 V at scan rates of 50 mV/s.…”
Section: Methodsmentioning
confidence: 99%
“…Despite the benefits of micro-scale electrodes, challenges with measuring DNA hybridization using microelectrodes have been encountered including inconsistent SAM layer formation, with it being necessary to modify the SAM forming conditions to achieve consistent film formation on small electrodes, and difficulties associated with interpreting the impedance behavior at a DNA modified microelectrode, i.e. selecting an appropriately sized electrode and suitable equivalent circuit to fit the response (Corrigan et al, 2018;. Additionally, factors which are not normally a problem for bulk gold electrodes can present an issue for thin film devices.…”
Section: Microelectrodesmentioning
confidence: 99%