2020
DOI: 10.3390/w12010240
|View full text |Cite
|
Sign up to set email alerts
|

A Simple Off-Grid Incubator for Microbiological Water Quality Analysis

Abstract: There is a need for accessible and low-cost microbiological water quality testing in contexts where diarrheal illness is a major public health concern. In most cases, the quantification of Escherichia coli and other microbial indicators by conventional culture methods requires an incubation step for processed samples at specific temperatures for bacterial growth over a prescribed time. However, incubators can be the most expensive equipment required for such microbial analyses, limiting the number and scope of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…Colilert media was added to 100 mL sample and mixed until dissolved completely. The solution was poured into an IDEXX Quanti-Tray/2000 and sealed using the Quanti-Tray sealer 26 . The samples were incubated at 35 °C for 24 h. Trays were scanned using a fluorescent UV lamp to count fluorescent wells positive for E. coli concentration and counted with the most probable number (MPN) table provided by the manufacturer 27 .…”
Section: Methodsmentioning
confidence: 99%
“…Colilert media was added to 100 mL sample and mixed until dissolved completely. The solution was poured into an IDEXX Quanti-Tray/2000 and sealed using the Quanti-Tray sealer 26 . The samples were incubated at 35 °C for 24 h. Trays were scanned using a fluorescent UV lamp to count fluorescent wells positive for E. coli concentration and counted with the most probable number (MPN) table provided by the manufacturer 27 .…”
Section: Methodsmentioning
confidence: 99%
“…Current innovative incubator designs have made use of heated foam ice boxes [3] or food chiller boxes [1] powered by a 12 V car battery or similar flexible power supplies. Such designs have made use of widely available and inexpensive temperature control modules, coupled to resistive heater panels and fans [11] .…”
Section: Hardware In Contextmentioning
confidence: 99%
“…Crucially, the long incubation period and reliable electricity source required by these methods limits their feasibility for routine, rapid, on-site monitoring. Although research has been done to eliminate the need for electricity by using homemade incubators, these systems are not widely used (Bernardes et al, 2020). In recent years, new culture-based methods have been developed including TECTA (Bramburger et al, 2015) and Compartment Bag Tests (CBTs; Brooks et al, 2017;Wang et al, 2017).…”
Section: Introductionmentioning
confidence: 99%