2010
DOI: 10.1016/j.jpba.2009.02.018
|View full text |Cite
|
Sign up to set email alerts
|

Achiral liquid chromatography with circular dichroism detection for the determination of carnitine enantiomers in dietary supplements and pharmaceutical formulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 34 publications
0
8
0
Order By: Relevance
“…Also, the published ECD spectrum is somewhat ambiguous, since it was measured with an HPLC-CD detector. 9 We decided then to repeat the measurements of the ECD spectra on a dedicated instrument. The results are given in Figure 5 for L-and D-acetyl carnitine in hydrochloride (3) (panel A) and zwitterionic forms (panel B), for L-and D-propyonil carnitine in hydrochloride form (2) (panel C), and for L-and D-carnitine in zwitterionic form (panel D).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, the published ECD spectrum is somewhat ambiguous, since it was measured with an HPLC-CD detector. 9 We decided then to repeat the measurements of the ECD spectra on a dedicated instrument. The results are given in Figure 5 for L-and D-acetyl carnitine in hydrochloride (3) (panel A) and zwitterionic forms (panel B), for L-and D-propyonil carnitine in hydrochloride form (2) (panel C), and for L-and D-carnitine in zwitterionic form (panel D).…”
Section: Resultsmentioning
confidence: 99%
“…Fast, accurate, and reproducible analytical methods capable to measure the enantiomeric excess of the final material are also highly desired 6 : in this field it is nice to acknowledge the seminal contribution of Professor Gasparrini and his group. 7,8 Carnitine and acyl carnitines being chiral molecules, optical rotation (OR) and circular dichroism in the UV range (electronic circular dichroism, ECD) were measured 9 ; in the latter case, ECD has been used as a detector of enantiomeric separation, down the line of HPLC separation protocol, without the accuracy required in a dedicated ECD experiment. To the best of our knowledge, though, no one has ever measured vibrational circular dichroism (VCD); yet various forms of vibrational spectroscopy, including IR, Raman, and SERS (surface-enhanced Raman spectroscopy) have been carried out and demonstrated to be useful.…”
Section: Abstract: Vibrational Circular Dichroism (Vcd); Carnitine; mentioning
confidence: 99%
“…The best performing drug substances in this study had LOQs nearly equivalent to those of previous literature reports. Recall that these studies sought to optimize conditions favorable to CD detection rather than focus on compatibility with validated methods, and in doing so, were able to achieve LOQs around 0.5% [10,12,16,19]. The use of organic mobile phase components in the USP methods likely resulted in slightly poorer performance, but nevertheless, most LOQs were near this level.…”
Section: Resultsmentioning
confidence: 99%
“…Shell particles are a relatively recent trend in chromatographic separation, but several pharmaceutical-bioanalytical [105][106][107][108][109][110][111][112][113][114][115][116][117][118], food analytical [119][120][121][122][123][124][125][126][127][128][129], environmental [130][131][132][133][134] and multidimensional [135][136][137] separations can be found in the literature. Very recently, new commercially available wide-pore stationary phases demonstrate exceptional efficiency for protein separations [138][139][140].…”
Section: Superficially Porous Particlesmentioning
confidence: 99%