2015
DOI: 10.1109/jsen.2015.2441651
|View full text |Cite
|
Sign up to set email alerts
|

An Analysis and Design of Photonic Crystal-Based Biochip for Detection of Glycosuria

Abstract: In this paper, a 2-dimensional "Air holes in silicon slab" photonic crystal based structure with line defect has been designed and simulated for detection of high glucose concentration in urine from 0-15 mg/dl to 10 gm/dl in the wavelength range of 1530-1565 nm. High glucose concentration in urine is referred as "Glycosuria". The proposed sensor structure is modeled and simulated in time domain by using MEEP (MIT Electromagnetic Equation Propagation) simulation tool. Finite Difference Time Domain (FDTD) method… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(12 citation statements)
references
References 29 publications
0
12
0
Order By: Relevance
“…Typically, PC is having PBG, which is entirely broken by introducing either line defect or point defect. By breaking the defects, PC based optical devices, such as filter [14,15], directional coupler [16], demultiplexer [17,18], triplexer [19,20], power splitter [21,22], logic gates [23], switches [24,25], electro-optical modulators [26,27], add-drop filter [28,29], and sensors [30][31][32][33][34][35][36][37][38][39][40][41], were reported.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Typically, PC is having PBG, which is entirely broken by introducing either line defect or point defect. By breaking the defects, PC based optical devices, such as filter [14,15], directional coupler [16], demultiplexer [17,18], triplexer [19,20], power splitter [21,22], logic gates [23], switches [24,25], electro-optical modulators [26,27], add-drop filter [28,29], and sensors [30][31][32][33][34][35][36][37][38][39][40][41], were reported.…”
Section: Introductionmentioning
confidence: 99%
“…In the literature, PC/PCRR based sensors were reported for bio sensing applications [30,31], salinity sensor for different temperatures [32], chemical sensor [33], force/strain sensor applications [34,35], pressure sensor [36], biosensor to detect the glucose concentration in urine [5,37,38], aqueous environment [39], breast cancer [40], cancer cell detection [41], pregnancy test, etc. In this paper, a photonic crystal based biosensor is designed, and sensing characteristics such as the Q factor, resonant wavelength, and normalized output power are estimated for albumin, bilirubin, urea, and glucose in urine and also glucose concentration in blood.…”
Section: Introductionmentioning
confidence: 99%
“…50 These materials are often made from silica or indium oxide, carefully constructed and modified for their chemical and optical properties. [51][52][53][54][55][56][57] The optical properties of PCs are related to their periodicity, size, and average refractive index. 51 Sharma and Sharan 52,53 detected high glucose concentration in urine, known as glycosuria, using a PC-based structure with line defects and 2D air holes in a silicon slab.…”
Section: Pc-based Biosensorsmentioning
confidence: 99%
“…Additionally, due to the introduction of marker molecules, it is possible for the structure and activity of the biological molecules to be affected and changed, usually making the test results difficult to demonstrate the interaction of biological molecules and the authenticity of the characteristics [ 7 , 8 ]. Based on the aforementioned reasons, the non-mark detection technology has gradually become an important development direction in the field of biological analysis in recent years [ 9 , 10 , 11 , 12 , 13 ].…”
Section: Introductionmentioning
confidence: 99%