2009
DOI: 10.1109/tie.2009.2013846
|View full text |Cite
|
Sign up to set email alerts
|

Cascaded Multilevel Inverter Employing Three-Phase Transformers and Single DC Input

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
17
0
2

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 144 publications
(22 citation statements)
references
References 33 publications
1
17
0
2
Order By: Relevance
“…This configuration use single DC input and require additional single and three phase transformers for higher voltage level. In accordance with the observation from the references [5]- [7], inverter topology requires more DC input, transformers and switches which result in increased complexity, system size and cost. For maintain grid current as pure sinusodial Proportional-Integral (PI) controller and FLC controllers are used as feedback controller.…”
Section: Introductionsupporting
confidence: 55%
See 3 more Smart Citations
“…This configuration use single DC input and require additional single and three phase transformers for higher voltage level. In accordance with the observation from the references [5]- [7], inverter topology requires more DC input, transformers and switches which result in increased complexity, system size and cost. For maintain grid current as pure sinusodial Proportional-Integral (PI) controller and FLC controllers are used as feedback controller.…”
Section: Introductionsupporting
confidence: 55%
“…Table 1 shows THD profile of exiting work. [20] 2013 Three Phase 5Levels SVPWM 9.0% Table 2 shows the comparison of a number of power devices used in the proposed approach with two existing approaches inferred in [5] and [7]. In the proposed work the numbers of switches are reduced to fifteen when compared to 24 in [5,7].…”
Section: Performance Analysis Of Pi and Fuzzy Logic Controllermentioning
confidence: 99%
See 2 more Smart Citations
“…Several asymmetrical topologies have been brought out along with a requirement for high frequency switching devices and ability to withstand overall voltage, which restricts their use for high voltage applications [15][16][17][18][19][20]. A topology based on series parallel connection of dc sources to produce higher number of levels has not been in surface due to the different rating of power components and its associated increase in the overall cost [15].…”
Section: Introductionmentioning
confidence: 99%