2018
DOI: 10.1080/00393630.2018.1486530
|View full text |Cite
|
Sign up to set email alerts
|

Characterisation of VOCs Surrounding Naum Gabo’s Construction in Space ‘Two Cones’, (Tate) by in situ SPME GC-MS Monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
10
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 6 publications
1
10
0
Order By: Relevance
“…The study also found increased hydrophilicity in areas of the film affected by microbubble formation [85]. In other studies, TPP's hydrolysis products of phenol and diphenyl phosphate have been detected, suggesting plasticiser and migration of by-products can also occur [4,86].…”
Section: Factors Affecting Migrationsupporting
confidence: 54%
See 2 more Smart Citations
“…The study also found increased hydrophilicity in areas of the film affected by microbubble formation [85]. In other studies, TPP's hydrolysis products of phenol and diphenyl phosphate have been detected, suggesting plasticiser and migration of by-products can also occur [4,86].…”
Section: Factors Affecting Migrationsupporting
confidence: 54%
“…For example, active sampling in a stainless steel chamber using pumped air and TENAX sorbent tubes followed by ATD-GC/MS has been successfully used to detect and measure the concentration of volatile naphthalene pesticide residues [95]. Recently, Kearney et al showed the utility of SPME fibres for sorption of phthalates emitted from a visibly degraded object where it was not possible to sample via contact [4]. However, the variability of measurements in noncontrolled museum environments discounts their use in quantitative studies [96].…”
Section: Qualitative and Quantitative Methods For The Analysis Of Plamentioning
confidence: 99%
See 1 more Smart Citation
“…When cases are opened, VOC concentration decreases. However, after 24 h the VOCs concentration is again sufficiently high to be detected by SPME-GC-MS [18,19]. The selection of the sampling points was based on the visual observation of crystals made by the museum conservators and collection manager in a first exploratory phase.…”
Section: Display Cases and Exhibition Hall: On-site Samplingmentioning
confidence: 99%
“…The selection of the locations was based on the presence or absence of visible signs of efflorescence on objects observed during previous on-site condition surveys. SPME fibers were placed inside the cases for 24 h. A recent publication has shown a good compromise between sensitivity and prolonged exposure times of SPME fibers, allowing the accumulation of sufficient analyte onto the fiber within a reasonable timeframe [18,19]. However, it should be emphasized that long exposure times can create fluctuations on the extraction yield of the analytes.…”
Section: On-site Headspace Analysis Inside the Museum Gallery And Exhmentioning
confidence: 99%