2022
DOI: 10.1016/j.atmosenv.2021.118931
|View full text |Cite
|
Sign up to set email alerts
|

Connection between lung deposited surface area (LDSA) and black carbon (BC) concentrations in road traffic and harbour environments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
8
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(10 citation statements)
references
References 59 publications
2
8
0
Order By: Relevance
“…The probability distribution is shown for the LDSA to BC ratio in Figure 9 for both solid (Figure 9a, Period 1) and semi-volatile (Figure 9b, Period 2) dominant events. The ratio distribution remains fairly constant and bimodal during Period 1, for both LDSA ratios, showing similar results to the laboratory-grade instruments for near-road ratios [18]. However, Period 2 had drastically different distributions for the LDSA C and LDSA N to BC ratios.…”
Section: Ldsa and Bc Ratiossupporting
confidence: 66%
See 3 more Smart Citations
“…The probability distribution is shown for the LDSA to BC ratio in Figure 9 for both solid (Figure 9a, Period 1) and semi-volatile (Figure 9b, Period 2) dominant events. The ratio distribution remains fairly constant and bimodal during Period 1, for both LDSA ratios, showing similar results to the laboratory-grade instruments for near-road ratios [18]. However, Period 2 had drastically different distributions for the LDSA C and LDSA N to BC ratios.…”
Section: Ldsa and Bc Ratiossupporting
confidence: 66%
“…This correlation is evident in Figure 4a. All LDSA measurements peak around 40 µm 2 /cm 3 , typical of ranges measured along street canyons and urban centres with relatively good air quality [18,29]. There is a CO 2 concentration difference of 75 ppm from background, and the maximum BrC and BC concentrations (~3000 ng/m 3 ) reached in Period 1 were six times higher than average background concentrations (500 ng/m 3 ).…”
Section: Resultsmentioning
confidence: 90%
See 2 more Smart Citations
“…NO, NO 2 and ozone measurements were collected using the Box Of Clustered Sensors (BOCS; in the same time resolution, as well as black carbon (BC) concentrations using the MA200 sensor by Magee Scientific. Finally, the data for the lung-deposited surface area (LDSA) of particles in the range of 10 nm to 10 µm, which is found to strongly correlate with BC emissions (Lepistö et al, 2022), were collected using a set of two Naneos Partec-tors by Naneos Particle Solutions GmbH. One sensor measured the surface of all particles in this size range, while the second is placed after a catalytic stripper (Catalytic Instruments CS015) which removes the semi-volatile particles (Haugen et al, 2022).…”
Section: Location Of the Site And Instrumentsmentioning
confidence: 99%