1999
DOI: 10.1016/s0021-9673(99)00319-2
|View full text |Cite
|
Sign up to set email alerts
|

Contactless conductivity detection in capillary zone electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
21
0
4

Year Published

2001
2001
2007
2007

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(25 citation statements)
references
References 37 publications
0
21
0
4
Order By: Relevance
“…Slightly different CCD techniques were proposed for HPCE in 1998 [304,305] and subsequently improved (for reviews see refs. [306][307][308][309][310]). In CCD, the impedance is measured as a function of the cell capacitance value which depends on multiple factors, including the dielectric (conductivity) profile of environment and the geometry of cell and electrodes.…”
Section: Contact and Contactless Conductivity Detection (Cd Ccd C 4mentioning
confidence: 99%
See 1 more Smart Citation
“…Slightly different CCD techniques were proposed for HPCE in 1998 [304,305] and subsequently improved (for reviews see refs. [306][307][308][309][310]). In CCD, the impedance is measured as a function of the cell capacitance value which depends on multiple factors, including the dielectric (conductivity) profile of environment and the geometry of cell and electrodes.…”
Section: Contact and Contactless Conductivity Detection (Cd Ccd C 4mentioning
confidence: 99%
“…The BGE composition for use in CZE in combination with CD has been previously investigated, focusing on the optimization of separation conditions and detector response [306,312,313]. Conductivity-based assays were also optimized in a number of practical works relevant to the analysis of the L-arginine/NO pathway [101,179,[247][248][249][313][314][315][316][317].…”
Section: Contact and Contactless Conductivity Detection (Cd Ccd C 4mentioning
confidence: 99%
“…Os eletrodos da célula condutométrica constituem um capacitor enquanto a solução atua como uma resistência cujo valor depende de sua condutividade elé-trica. A detecção condutométrica foi empregada por Jensen e Parrack em análise titulométrica 19 e por Vacík e colaboradores 20 na separação de ânions inorgânicos 21,22 . Um detector oscilométrico desenvolvido por Fracassi da Silva e Lago 23 opera com freqüência de 600 kHz e 20 V pico-a-pico entre dois eletrodos cilíndricos distantes 1 mm entre si, os quais são construídos pintando-se duas faixas com tinta à base de prata sobre a superfície de um capilar, perpendicularmente ao seu eixo.…”
Section: Introductionunclassified
“…A separação de tensoativos também tem sido investigada por EC com detecção condutométrica 12,[19][20][21] , apresentando resultados favoráveis. Recentemente, a detecção condutométrica sem contato (DCSC), ou oscilométrica, foi introduzida em EC como alternativa à detecção condutométrica convencional [22][23][24][25][26][27] . Na DCSC são utilizadas altas freqüências de operação, em comparação à detecção condutométrica convencional, possibilitando o posicionamento dos eletrodos do lado externo do capilar.…”
Section: Introductionunclassified