2016
DOI: 10.1007/s11227-016-1833-5
|View full text |Cite|
|
Sign up to set email alerts
|

Development of a low-cost wearable sensing glove with multiple inertial sensors and a light and fast orientation estimation algorithm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
31
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 24 publications
(32 citation statements)
references
References 8 publications
0
31
0
Order By: Relevance
“…Y. Wong & Wong, 2008b) analyzed the trunk , five papers (Kuster et al, 2016;Vignais et al, 2013;Valero et al, 2016;Qin et al, 2014;Peppoloni et al, 2016) analyzed the movement of neck and shoulder, three paper (Holte et al, 2012;Antonio Diego-Mas et al, 2014;Botter et al,2013), analyzed posture. Other organs were analyzed in these studies: back (Valero et al, 2016), finger wrist (Botter et al, 2016;Choi, Yoo, Kang, Seo, & Kim, 2016;Schmuntzsch et al, 2013), head (Morency, Whitehill, & Movellan, 2010), seated posture (Albert et al, 2014;Karakolis et al, 2016), hip and knee and ankle (Menguec et al, 2013) were analyzed.…”
Section: Resultsmentioning
confidence: 99%
“…Y. Wong & Wong, 2008b) analyzed the trunk , five papers (Kuster et al, 2016;Vignais et al, 2013;Valero et al, 2016;Qin et al, 2014;Peppoloni et al, 2016) analyzed the movement of neck and shoulder, three paper (Holte et al, 2012;Antonio Diego-Mas et al, 2014;Botter et al,2013), analyzed posture. Other organs were analyzed in these studies: back (Valero et al, 2016), finger wrist (Botter et al, 2016;Choi, Yoo, Kang, Seo, & Kim, 2016;Schmuntzsch et al, 2013), head (Morency, Whitehill, & Movellan, 2010), seated posture (Albert et al, 2014;Karakolis et al, 2016), hip and knee and ankle (Menguec et al, 2013) were analyzed.…”
Section: Resultsmentioning
confidence: 99%
“…However, their data glove was only able to transmit its data through a USB interface, which was prone to be restricted by the environment. Choi et al developed a data glove with a fast orientation algorithm to effectively calculate the Euler angles [2]. But their data glove produced higher error than the proposed data glove.…”
Section: Discussionmentioning
confidence: 99%
“…The users are not required to wear any devices, but such systems are easily affected by environmental conditions, such as illumination and occlusion. By contrast, contact-based designs are more practical in medical settings [1][2][3][4][5][6][7]12]. Data gloves are the most popular type of contact-based design.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations