2011
DOI: 10.3109/0284186x.2011.582516
|View full text |Cite
|
Sign up to set email alerts
|

Dose determination using alanine detectors in a mixed neutron and gamma field for boron neutron capture therapy of liver malignancies

Abstract: (2011) Dose determination using alanine detectors in a mixed neutron and gamma field for boron neutron capture therapy of liver malignancies, Acta Oncologica, 50:6, 817-822,

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…Alanine irradiations in tissue and a polymethylmethacrylate (PMMA) phantom have been described in detail before. 29 In those experiments, six pellets were irradiated in tissue (dissected liver lobe) and ten pellets in cuboid-shaped PMMA phantom (10 × 10 × 23 cm). For this paper, data from the previous experiments were recalculated with the enhanced model of the TRIGA Mainz (see accompanying paper: Confirmation of an elaborate computer model for BNCT dosimetry at the TRIGA Mainz).…”
Section: A Experimentalmentioning
confidence: 99%
“…Alanine irradiations in tissue and a polymethylmethacrylate (PMMA) phantom have been described in detail before. 29 In those experiments, six pellets were irradiated in tissue (dissected liver lobe) and ten pellets in cuboid-shaped PMMA phantom (10 × 10 × 23 cm). For this paper, data from the previous experiments were recalculated with the enhanced model of the TRIGA Mainz (see accompanying paper: Confirmation of an elaborate computer model for BNCT dosimetry at the TRIGA Mainz).…”
Section: A Experimentalmentioning
confidence: 99%
“…The accuracy of the new source plane has been investigated through comparison of the criticality calculations with experimental results. Therefore a PMMA-and a polytetrafluorethylen (PTFE)-phantom equipped with alanine dosimeters and gold foils were irradiated and measurements on a human liver tissue received in a clinical trial described earlier 23,24 were made.…”
Section: Introductionmentioning
confidence: 99%
“…These features allowed alanine to be classified as a reference standard dosimetry system by the IAEA for the measurement of high doses [22]. EPR detectors show a behavior that suggest a possible extension of their use also in hadrontherapy with protons, carbon ions [23,24] and neutrons [17,19,[25][26][27][28][29][30][31]. Alanine/EPR dosimetry is suitable for IORT dosimetry because alanine response has found to be independent of the dose rate even for the high dose rates used in this radiotherapeutic technique [7].…”
Section: Introductionmentioning
confidence: 98%