2001
DOI: 10.1016/s0003-2670(00)01191-0
|View full text |Cite
|
Sign up to set email alerts
|

Dual photometric-contactless conductometric detector for capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
76
1

Year Published

2001
2001
2005
2005

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 75 publications
(79 citation statements)
references
References 16 publications
2
76
1
Order By: Relevance
“…In the further development of the CCD cell design, the electrodes have been based on soldered coils of copper wire [25,26] or on strips of aluminium foil [27,28]. The basic cell configuration in all these designs is, however, almost identical and is illustrated in Figure 1A.…”
Section: Basic Principles Of Contactless Conductivity Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the further development of the CCD cell design, the electrodes have been based on soldered coils of copper wire [25,26] or on strips of aluminium foil [27,28]. The basic cell configuration in all these designs is, however, almost identical and is illustrated in Figure 1A.…”
Section: Basic Principles Of Contactless Conductivity Detectionmentioning
confidence: 99%
“…Chvojka et al [26] designed a dual photometric-contactless conductivity detector for simultaneous absorbance and conductivity measurements of both inorganic and organic ions. Tù ma et al [27] demonstrated that semitubular electrodes can be utilized for the construction of a CCD cell, which can be opened up for easy exchange of the capillary.…”
Section: Instrumental Developmentsmentioning
confidence: 99%
“…The contactless conductivity detector has been used for CE detection of anions with a-CD to promote separation [183], and in the characterization of purity of alkyl-and arylamino derivatives of b-cyclodextrin [184]. A combined system with simultaneous contactless conductivity and photometric detectors has been also reported recently [185]. Fig.…”
Section: Conductivity Detection In Cementioning
confidence: 99%
“…For example, UV has been combined with conductivity detection, 3,4 with amperometric detection 5 and with mass spectrometry 6,7 for CE. Recently, Jelınek et al 8,9 designed a dual photometric-contactless conductometric detector for CE where two detections were simultaneously carried out at the same place in the separation capillary. FD is a highly sensitive and selective, and is frequently used in CE for analysis of the biochemical samples.…”
Section: Introductionmentioning
confidence: 99%