1988
DOI: 10.1366/0003702884429625
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Mini-Hollow Cathode Emission Source for the Analysis of Microsamples

Abstract: The analysis of very small samples by atomic emission from a hollow cathode discharge source is investigated. Subpicogram detection limits of 0.88, 0.72, 0.38, and 0.70 pg are reported for Li, Na, K, and Ca, respectively, by viewing the excitation from a very small hollow with a custom-built multichannel spectrometer. These detection limits are comparable to those from electrothermal atomic absorption, with the additional advantage of the ability to analyze nonmetals. The technique has adequate sensitivity for… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
7
0

Year Published

1991
1991
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 17 publications
0
7
0
Order By: Relevance
“…7,8 It is natural to wonder if the scope of application of GD devices can be extended to liquid-phase samples. [9][10][11][12][13][14] This is not unlike the attempts to deliver solid-phase originating samples into atmospheric pressure plasma sources (instead of the more natural solution introduction methods) by means of laser ablation or slurry aspiration. 15,16 While the cathodic sputtering in traditional GD sources effectively yields neutral atoms and molecules from solid matrices, the discharge's gas phase temperature (300-500 K) and low density are insufficient to affect desolvation of analytes introduced in water vapor, for example.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…7,8 It is natural to wonder if the scope of application of GD devices can be extended to liquid-phase samples. [9][10][11][12][13][14] This is not unlike the attempts to deliver solid-phase originating samples into atmospheric pressure plasma sources (instead of the more natural solution introduction methods) by means of laser ablation or slurry aspiration. 15,16 While the cathodic sputtering in traditional GD sources effectively yields neutral atoms and molecules from solid matrices, the discharge's gas phase temperature (300-500 K) and low density are insufficient to affect desolvation of analytes introduced in water vapor, for example.…”
Section: Introductionmentioning
confidence: 99%
“…A good deal of effort has been devoted to developing strategies of introducing liquid-originating analytes into the discharge environment. [9][10][11][12][13][14] In an approach similar to that used in graphite furnace AAS, drying an aliquot of the analytecontaining solution on a suitable target cathode provides the GD with a dry residue sample that can be sputtered into the plasma. 9,10 In this way solvent vapors, which have a deleterious effect on GD source energetics, 17,18 are excluded from the discharge volume.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although the cathodic sputtering event entails sufficient energy to release neutral atoms and molecules from solid matrixes, the discharge's gas-phase temperature is insufficient to affect desolvation of analytes introduced in water vapor, as is typical in atmospheric pressure flames and plasmas. As such, a good deal of effort has been devoted to developing strategies of getting liquid-originating analytes into the discharge environment. The most common method involves drying an aliquot of analyte-containing solution on an inert target that is subsequently introduced as the cathode of the GD source, and the dried residue is sputtered from its surface. , In this way, solvent vapors are excluded from the discharge volume, and the plasma is operated much in its normal manner. Although effective, this approach is laborious and is not amenable to what would ideally be the analysis of flowing streams, such as liquid chromatograph eluents.…”
mentioning
confidence: 99%
“…As such, a good deal of effort has been devoted to developing strategies of getting liquid-originating analytes into the discharge environment. [8][9][10][11][12][13] The most common method involves drying an aliquot of analyte-containing solution on an inert target that is subsequently introduced as the cathode of the GD source, and the dried residue is sputtered from its surface. 8,9 In this way, solvent vapors are excluded from the discharge volume, and the plasma is operated much in its normal manner.…”
mentioning
confidence: 99%