This paper presents an experimental research work that evaluates the pre-stress loss caused by friction in crushed limestone sand (CLS) concrete members with post-tensioning. A total of 26 full-scale pre-stressed concrete beams were constructed and tested for the friction loss experiment. The considered variables mainly included the duct-forming materials, wires of tendons and arrangement of ducts. The tensile forces at both active and passive ends of specimen were recorded by steps, and then the pre-stress friction loss for each case was calculated. The result shows that the proportion of pre-stress friction loss in specimen with multi-wire tendons is in the range of 10-40%, with the trend first increasing before decreasing. The pre-stress friction loss in specimen with curve duct accounts for 10-30%. The pressure on the curved part definitely increases the friction when compared with the straight duct. The pre-stress friction loss in specimen with rubber hose reaches nearly 40%, which is larger than the metal bellow and plastic bellow. The suggested values for each case are proposed for a deviation coefficient κ of 0.0017-0.007 and a friction coefficient µ of 0.108-0.858. This can provide reliable theoretical support for the design and construction.