2005
DOI: 10.1021/ac050160z
|View full text |Cite
|
Sign up to set email alerts
|

Geometry-Independent Plate Height Representation Methods for the Direct Comparison of the Kinetic Performance of LC Supports with a Different Size or Morphology

Abstract: The advantages of representing experimental plate height data as a plot of Kv/u0(2) or H2/Kv versus Kv/(Hu0) instead of as H versus u0 are discussed (Kv=column permeability). Multiplying the values on both axes by the ratio of a reference pressure drop and mobile-phase viscosity, the obtained plots directly yield the kinetic performance limits of the tested support structure, without any need for further numerical optimization. Directly showing the range of plate numbers or analysis times wherein the tested su… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
198
1

Year Published

2009
2009
2020
2020

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 258 publications
(202 citation statements)
references
References 25 publications
(63 reference statements)
3
198
1
Order By: Relevance
“…As shown elsewhere [27,36], the low b-coefficient in HILIC compared with RP can be mainly attributed to the reduced surface diffusion contributions due to elements of localisation in the retention mechanism and the presence of a water layer on the column surface, which restricts surface diffusion. Interestingly, Table 4 indicates that the particle morphology has only a small influence on the axial diffusion behaviour in HILIC, as shown by the rather similar reduced bcoefficients (range 2.04-2.37) for cytosine on the 4 columns from arrested elution experiments.…”
Section: Arrested Elution and Reduced Van Deemter Analysismentioning
confidence: 79%
See 1 more Smart Citation
“…As shown elsewhere [27,36], the low b-coefficient in HILIC compared with RP can be mainly attributed to the reduced surface diffusion contributions due to elements of localisation in the retention mechanism and the presence of a water layer on the column surface, which restricts surface diffusion. Interestingly, Table 4 indicates that the particle morphology has only a small influence on the axial diffusion behaviour in HILIC, as shown by the rather similar reduced bcoefficients (range 2.04-2.37) for cytosine on the 4 columns from arrested elution experiments.…”
Section: Arrested Elution and Reduced Van Deemter Analysismentioning
confidence: 79%
“…By using the approach of Desmet et al [27] projection of column performance can be achieved by transforming non-reduced van Deemter data into so-called kinetic plots. Figs.…”
Section: Practical Performance Evaluationmentioning
confidence: 99%
“…2-8 m through-pores and 1-2 m skeletons, that the through-pores and skeletons of the first generation monolithic columns were too large and the external porosity too high. In other words, they suggested to compromise the major characteristics of monolithic silica for higher column efficiency 108 . The presence of through-pores of ca.…”
Section: Improvements Proposed Based On the Characterization Of Firstmentioning
confidence: 99%
“…The concept of kinetic column performance was introduced by Giddings (1964Giddings ( , 1965a and was later revisited by Knox and Saleem (1969), Poppe (1997), Desmet et al (2005), and Desmet et al (2006). Compared to traditional Heu 0 curves, the kinetic plot representation delivers a highly relevant performance measure: the analysis time required to produce a desired number of plates.…”
Section: Kinetic Column Performancementioning
confidence: 99%
“…Experimental Heu and permeability data can be directly converted to a kinetic plot through (Desmet et al, 2005) (6.36) and…”
Section: Coreeshell Particles 197mentioning
confidence: 99%