2013 Africon 2013
DOI: 10.1109/afrcon.2013.6757800
|View full text |Cite
|
Sign up to set email alerts
|

Harmonic levels of domestic and electrical vehicle loads in residential distribution networks

Abstract: Purpose of the present paper is to provide the results of the study performed in order to assess current distortion of domestic and electrical vehicle (EV) loads and corresponding voltage distortion in the residential distribution networks. For the study harmonic current amplitudes and phase angles of different home appliances were measured and afterwards the corresponding models were composed in DIgSILENT Power Factory. The focus of the study was to analyse the characteristics of the residential distribution … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
3

Relationship

2
8

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 12 publications
0
9
0
Order By: Relevance
“…In order to model the network response of nonlinear loads, 14 different home appliances were measured. The results of the corresponding measured active and reactive power, harmonic current magnitudes and harmonic current phase shift angles of measured devices are presented in [15] [16]. Modelled devices were arranged in a manner where similar active power consumption was seen in every phase.…”
Section: Methodsmentioning
confidence: 99%
“…In order to model the network response of nonlinear loads, 14 different home appliances were measured. The results of the corresponding measured active and reactive power, harmonic current magnitudes and harmonic current phase shift angles of measured devices are presented in [15] [16]. Modelled devices were arranged in a manner where similar active power consumption was seen in every phase.…”
Section: Methodsmentioning
confidence: 99%
“…The results of the corresponding measured active and reactive power, harmonic current magnitudes and harmonic current phase shift angles of measured devices are presented in [26] [27]. Modelled devices were arranged in a manner where similar active power consumption was seen in every phase.…”
Section: Methodsmentioning
confidence: 99%
“…Nonlinear loads, when supplied with sinusoidal voltage sources, produce harmonics in the supply waveform and consequently affect the operation of other linear devices connected to the distribution grid. Various studies have investigated the harmonic effects of nonlinear loads on the distribution grid [20][21][22][23][24][25][26][27][28][29][30][31][32]. A novel scheme for mitigating harmonic problems caused by LV devices in residential distribution systems was presented in [20].…”
Section: Introductionmentioning