2018
DOI: 10.1109/tmtt.2017.2721407
|View full text |Cite
|
Sign up to set email alerts
|

High-Accuracy Heart Rate Variability Monitoring Using Doppler Radar Based on Gaussian Pulse Train Modeling and FTPR Algorithm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
64
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 99 publications
(65 citation statements)
references
References 39 publications
1
64
0
Order By: Relevance
“…Also, in the previous research [17], even though the time window length is short, DCT has been shown to achieve the high HR estimation accuracy, compared with FFT. In addition to these HR estimation methods, M. Nosrati et al have introduced the FTPR (Frequency Time Phase Regression) algorithm for the accurate HR estimation [18], however, this method requires long time window, i.e., 10 s.…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, in the previous research [17], even though the time window length is short, DCT has been shown to achieve the high HR estimation accuracy, compared with FFT. In addition to these HR estimation methods, M. Nosrati et al have introduced the FTPR (Frequency Time Phase Regression) algorithm for the accurate HR estimation [18], however, this method requires long time window, i.e., 10 s.…”
Section: Related Workmentioning
confidence: 99%
“…Thus, the use of a Doppler sensor has been investigated in the field of not only the heartbeat detection [5]- [28], but also the respiration detection [29]- [31] and the activity recognition [32]- [34]. In the Doppler sensorbased heartbeat detection, (i) the HR [5]- [17] and the RRI (R-R Interval) [18]- [27] are typically estimated. In general, the HR is estimated mainly based on the frequency analysis such as FFT (Fast Fourier Transform) and MSUIC (Multiple Signal Classification).…”
Section: Introductionmentioning
confidence: 99%
“…The most important vital signs utilized in the related works summarized above are HR, FD, SpO2, and ECG [6][7][8][9][10][11][12][13][14]21]. HR and FD are the most significant signals considered in this work.…”
Section: Related Workmentioning
confidence: 99%
“…For an Indented Radar system, Equation (15) should be modified as it would be subject to Amplitude and DC imbalance. By simulating different cases, it is observed that in DACM algorithm the effect of DC offset is more crucial than amplitude imbalance and other factors, as addressed in [24] and [9]. Thus, considering the DC offset imbalance, Equation (15) gets modified to Equation (19).…”
Section: Dacmmentioning
confidence: 99%