High-speed high-accuracy fiber optic low-coherence interferometry for in situ grinding and etching process monitoring

Abstract: We present design of novel tool for characterization of wafer thickness and wafer topography employing fast low coherence fiber optic interferometer, which optical length of the reference arm of the interferometer is monitored by secondary long coherence length interferometer.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 2 publications
0
6
0
Order By: Relevance
“…We have reported use of this type of the apparatus for in-situ and ex-situ monitoring of semiconductor wafer grinding and chemical etching [5]. We reported both silicon [3], and compound materials applications [9], [12].…”
Section: Introductionmentioning
confidence: 97%
See 3 more Smart Citations
“…We have reported use of this type of the apparatus for in-situ and ex-situ monitoring of semiconductor wafer grinding and chemical etching [5]. We reported both silicon [3], and compound materials applications [9], [12].…”
Section: Introductionmentioning
confidence: 97%
“…We reported both silicon [3], and compound materials applications [9], [12]. In past several systems were reported including multi-probe systems [8], and fast systems enabling applications capable to measure wafer thickness during grinding process [4,5]. Finally, the reference plane solutions have been invented allowing to reduce dependence of the measured signal on temperature variations [10].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The optical interferometric techniques using Mach-Zehnder interferometer configuration [14] and Michelson interferometer configuration [15] can be realized in the time domain, namely, white-light interferometry (WLI), or in the frequency domain, namely, optical coherence tomography (OCT). The WLI approach based on low-coherence light sources and two arms is usually used as a slow distance or a slow displacement sensor [16] for the measurements of the thickness of silicon wafers [17] and distance in machine-made industrial [18]. To improve the measurement speed, the OCT approach is presented.…”
Section: Introductionmentioning
confidence: 99%