2014
DOI: 10.1128/iai.01525-13
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo Splenic Clearance Correlates with In Vitro Deformability of Red Blood Cells from Plasmodium yoelii-Infected Mice

Abstract: Recent experimental and clinical studies suggest a crucial role of mechanical splenic filtration in the host's defense against malaria parasites. Subtle changes in red blood cell (RBC) deformability, caused by infection or drug treatment, could influence the pathophysiological outcome. However, in vitro deformability measurements have not been directly linked in vivo with the splenic clearance of RBCs. In this study, mice infected with malaria-inducing Plasmodium yoelii revealed that chloroquine treatment coul… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
49
1
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 41 publications
(55 citation statements)
references
References 55 publications
4
49
1
1
Order By: Relevance
“…Specifically, when compared with deformable RBCs, the stiffer RBCs isolated by the μBM device displayed higher mechanical retention in the spleen, deteriorated osmotic fragility, and higher microparticle content. These results are in agreement with previous findings (174,178,181) and support the use of single RBC deformability as a biomarker to separate good RBCs from bad. Additionally, this margination system has already been tested for higher throughput (approximately 150 mL/h) using whole blood (167), making it a good candidate for clinical applications.…”
Section: Cleansing Banked Blood For Allogeneic Transfusionsupporting
confidence: 94%
See 1 more Smart Citation
“…Specifically, when compared with deformable RBCs, the stiffer RBCs isolated by the μBM device displayed higher mechanical retention in the spleen, deteriorated osmotic fragility, and higher microparticle content. These results are in agreement with previous findings (174,178,181) and support the use of single RBC deformability as a biomarker to separate good RBCs from bad. Additionally, this margination system has already been tested for higher throughput (approximately 150 mL/h) using whole blood (167), making it a good candidate for clinical applications.…”
Section: Cleansing Banked Blood For Allogeneic Transfusionsupporting
confidence: 94%
“…Although the details of this system have not been revealed, scaling microfluidic designs for processing larger volumes is reportedly a major hurdle. The Han group (177,178) is investigating the applicability of using the μBM cell sorter to remove bad RBCs from refrigerated blood. Since the μBM device could separate deformable RBCs from their stiffer counterparts, the rationale for using the μBM device to improve blood transfusion lies in the fact that RBC aging and damage occurring during ex vivo storage coincide with a decrease in cellular deformability (179,180).…”
Section: Cleansing Banked Blood For Allogeneic Transfusionmentioning
confidence: 99%
“…Similarly, only a minority of mature gametocytes exposed to DMSO and a majority of those exposed to calyculin were cleared. This strongly suggests that calyculin induces the clearance of mature gametocytes in vivo by inducing their mechanical retention in the spleen (39).…”
Section: Discussionmentioning
confidence: 99%
“…9 A separate work by Huang et.al also demonstrated on a malarial mice model that increased RBC stiffness associated with increased spleen mass and RBC retention. 15 Impaired deformability, therefore, may be an important biomarker for the old stored RBC subpopulation to be cleared post transfusion. 9, 15 …”
Section: Introductionmentioning
confidence: 99%