2005
DOI: 10.1016/j.jpba.2004.11.047
|View full text |Cite
|
Sign up to set email alerts
|

Identification of unknown impurities in simvastatin substance and tablets by liquid chromatography/tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
19
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(22 citation statements)
references
References 13 publications
3
19
0
Order By: Relevance
“…, m/z 419) is studied in detail using triple-quadrupole, ion-trap and Q-TOF instruments (Wang, Wu, & Zhao, 2001;Vuletić, Cindrić, & Koruznjak, 2005) (Wang, Wu, & Zhao, 2001), although an alternative structure has been suggested, involving a cleavage of the C-C bond at the hexahydronaphthalene ring with charge retention at the lactone ring (C 7 H 11 O 3 þ ; see Scheme 24). Interestingly, accurate-mass data indicate that both structure are observed, that is, the ion with C 7 H 11 O 3 þ at low collision energy, and the ion with C 11 H 11 þ at higher collision energy, which is in agreement with expectation based on the fragmentation pathways of both ions.…”
Section: Statinsmentioning
confidence: 99%
“…, m/z 419) is studied in detail using triple-quadrupole, ion-trap and Q-TOF instruments (Wang, Wu, & Zhao, 2001;Vuletić, Cindrić, & Koruznjak, 2005) (Wang, Wu, & Zhao, 2001), although an alternative structure has been suggested, involving a cleavage of the C-C bond at the hexahydronaphthalene ring with charge retention at the lactone ring (C 7 H 11 O 3 þ ; see Scheme 24). Interestingly, accurate-mass data indicate that both structure are observed, that is, the ion with C 7 H 11 O 3 þ at low collision energy, and the ion with C 11 H 11 þ at higher collision energy, which is in agreement with expectation based on the fragmentation pathways of both ions.…”
Section: Statinsmentioning
confidence: 99%
“…[21][22][23]27 However, C8 has been chosen because separation shows a slightly lower peak retention time (t R…”
Section: Resultsmentioning
confidence: 99%
“…20,21 Furthermore, LC-MS/MS was employed to identify SIM impurities or degradation products in bulk drug or tablets dosage form. 22,23 UV spectrometry, LC-UV and LC-MS have been reported to quantify SIM associated with other drugs such as ezetimibe, gemfibrozile or in multi-drugs formulation. [24][25][26][27] A micellar electrokinetic chromatographic (MEKC) method has been employed to quantify SIM and LOV in tablets.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This ensures that drug metabolism, safety and clinical studies are not jeopardized by inconsistent purity or impurities having potential harmful toxological properties. Regulatory guidelines promulgated by the International Conference on Harmonization (ICH) dictates rigorous identification of impurities at levels of 0.1% and greater depending upon dosage, followed by appropriate toxicological studies, if needed, for qualification [4].…”
Section: Introductionmentioning