2017
DOI: 10.1088/2058-6272/aa57f2
|View full text |Cite
|
Sign up to set email alerts
|

Long-pulse power-supply system for EAST neutral-beam injectors

Abstract: The long-pulse power-supply system equipped for the 4 MW beam-power ion source is comprised of three units at ASIPP (Institute of Plasma Physics, Chinese Academy of Sciences): one for the neutralbeam test stand and two for the EAST neutral-beam injectors (NBI-1 and NBI-2, respectively). Each power supply system consists of two low voltage and high current DC power supplies for plasma generation of the ion source, and two high voltage and high current DC power supplies for the accelerator grid system. The opera… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…The EAST is a medium size (major radius R = 1.85 m and minor radius a = 0.45 m) fully superconducting tokamak which aims at steady-state operation. The EAST tokamak has two NBI systems (each consist of two ion sources) with a maximum power of 8 MW (4 × 2 MW) [14,15]. As shown in figure 1(a), one of the NBI systems is a co-tangential unit at A port (named 'Co-NBI') and the another one is a countertangential unit at F port (named 'Ctr-NBI'), they can provide toroidal momentum injection along/against the direction of the plasma current respectively.…”
Section: Experimental Setup and Key Diagnosticsmentioning
confidence: 99%
“…The EAST is a medium size (major radius R = 1.85 m and minor radius a = 0.45 m) fully superconducting tokamak which aims at steady-state operation. The EAST tokamak has two NBI systems (each consist of two ion sources) with a maximum power of 8 MW (4 × 2 MW) [14,15]. As shown in figure 1(a), one of the NBI systems is a co-tangential unit at A port (named 'Co-NBI') and the another one is a countertangential unit at F port (named 'Ctr-NBI'), they can provide toroidal momentum injection along/against the direction of the plasma current respectively.…”
Section: Experimental Setup and Key Diagnosticsmentioning
confidence: 99%
“…The circuit connection of power supplies for the ion source is shown in figure 2 [18]. A filament power supply (DC 20 V@ 5.5 kA) and an arc power supply (DC 176 V@ 2 kA) are applied for the plasma generation.…”
Section: The High Power Ion Source On East-nbimentioning
confidence: 99%
“…The test platform consists of a radio frequency ion source and its supporting systems. The supporting systems include a vacuum chamber, a power supply system, an auxiliary pumping system, a gas supply unit, and a control system [2]. As an important part of the ion source performance test platform, the control system needs to keep each system stable and orderly, to provide an important guarantee for the smooth development of the experiment.…”
Section: Introductionmentioning