2015
DOI: 10.1016/j.mric.2015.04.004
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic Resonance Angiography of the Upper Extremity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 68 publications
(88 reference statements)
0
7
0
Order By: Relevance
“…Images can be analysed with subtraction technique, which improves contrast resolution, or without subtraction technique, thus allowing visualisation of the background. Although not recommended for quantitative perfusion analysis, timeresolved sequences are ideal for visual analysis of the hand vasculature and provide a vascular map and haemodynamic information, including inflow in the vessels or arrival times to the tissue [1,3,18]. For the evaluation of the hand, we use a time-resolved 3D sequence with a repetition time (TR) of 4.4-7.9 ms and a minimal echo time (TE min), 20-30° flip angle, a field of view (FOV) of approximately 15 cm, an approximately 224 × 256 matrix, and a 1.8-2.0-mm slice thickness.…”
Section: (B) Mrimentioning
confidence: 99%
See 3 more Smart Citations
“…Images can be analysed with subtraction technique, which improves contrast resolution, or without subtraction technique, thus allowing visualisation of the background. Although not recommended for quantitative perfusion analysis, timeresolved sequences are ideal for visual analysis of the hand vasculature and provide a vascular map and haemodynamic information, including inflow in the vessels or arrival times to the tissue [1,3,18]. For the evaluation of the hand, we use a time-resolved 3D sequence with a repetition time (TR) of 4.4-7.9 ms and a minimal echo time (TE min), 20-30° flip angle, a field of view (FOV) of approximately 15 cm, an approximately 224 × 256 matrix, and a 1.8-2.0-mm slice thickness.…”
Section: (B) Mrimentioning
confidence: 99%
“…They are frequently responsible for a visible mass or an enlarged finger. Low-flow malformations are much more frequent than high-flow malformations [1,5,7,9,14,26,56,[61][62][63][64]. They may affect the skin with a colour change (red or blue).…”
Section: Vascular Malformationsmentioning
confidence: 99%
See 2 more Smart Citations
“…7 The additional advantages of balanced field turbo echo MRA are high spatial resolution and large scan volume, which enables imaging of the entire thorax and abdomen without patient or coil reallocation during the scan. 8 The purpose of this study was to determine the type and frequency of vascular and organ malformations in adults with TE using non-contrast MRA and to assess the effect of the observed malformations on renal function.…”
Section: Classification Of Upper Limb Dysmelia and Eye Ear Or Facialmentioning
confidence: 99%