2006
DOI: 10.1364/josab.23.001001
|View full text |Cite
|
Sign up to set email alerts
|

Magnetometry with millimeter-scale antirelaxation-coated alkali-metal vapor cells

Abstract: Dynamic nonlinear magneto-optical-rotation signals with frequency-and amplitude-modulated laser light have been observed and investigated with a spherical glass cell of 3-mm diameter containing Cs metal with inner walls coated with paraffin. Intrinsic Zeeman relaxation rates of γ/(2π) ≈ 20 Hz and lower have been observed. Favorable prospects of using millimeter-scale coated cells in portable magnetometers and secondary frequency references are discussed.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
48
0
1

Year Published

2007
2007
2023
2023

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 83 publications
(49 citation statements)
references
References 19 publications
0
48
0
1
Order By: Relevance
“…Miniaturization of the vapor cells to millimeter scales can be done using more or less standard techniques (see, for example, Ref. [55] for a description of a prototype optical-rotation magnetometer using a 3-mm diameter paraffin-coated Cs cell). Another approach, particularly appealing for future mass production of miniaturized lowcost magnetometers, is manufacturing of an integrated sensor package incorporating a VCSEL laser, an alkalivapor cell, optics, and a detector using the wafer production techniques well developed by the semi-conductor industry.…”
Section: Additional Characteristics Of a Magnetometermentioning
confidence: 99%
“…Miniaturization of the vapor cells to millimeter scales can be done using more or less standard techniques (see, for example, Ref. [55] for a description of a prototype optical-rotation magnetometer using a 3-mm diameter paraffin-coated Cs cell). Another approach, particularly appealing for future mass production of miniaturized lowcost magnetometers, is manufacturing of an integrated sensor package incorporating a VCSEL laser, an alkalivapor cell, optics, and a detector using the wafer production techniques well developed by the semi-conductor industry.…”
Section: Additional Characteristics Of a Magnetometermentioning
confidence: 99%
“…While small cells can be fabricated with the method described above, 63,112 there are several significant detracting features. One is that the cells must be made one by one; fabricating large numbers of cells therefore takes considerable time.…”
Section: B Cell Fabricationmentioning
confidence: 99%
“…An EIT linewidth as narrow as 1 Hz has been realized in such paraffin-coated cells (no buffer gas) [34]; and recent improvements in coating materials have enabled coherence lifetimes as long as a minute [82,83]. Coated cells are actively being used for magnetometer [84], atomic clock [85], and quantum optics [86][87][88] applications. In comparison to buffer gas cells, coated cells do not suffer from collisional decoherence of excited states due to the buffer gas, which destroys quantum correlations in heralded photon generation experiments [89].…”
Section: Dual-structure Eit Lineshapes In Cells With Anti-relaxation mentioning
confidence: 99%