Mechanical Aspects of Stapedial Substitution: An Experimental Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0
2

Year Published

1974
1974
2006
2006

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 13 publications
0
1
0
2
Order By: Relevance
“…The mass of the prosthesis and its effect on gain in hearing has been well‐studied in animals 10,11 . The ideal prosthesis would be similar in mass to the stapes and exert no increased weight on the oval window at rest.…”
Section: Discussionmentioning
confidence: 99%
“…The mass of the prosthesis and its effect on gain in hearing has been well‐studied in animals 10,11 . The ideal prosthesis would be similar in mass to the stapes and exert no increased weight on the oval window at rest.…”
Section: Discussionmentioning
confidence: 99%
“…Recordemos que también se han realizado estudios tratando de que las prótesis tengan la misma masa que el estribo, lo cual puede dar ganancia en la audición, pero los informes no muestran mayores cambios. 16,17 Además, se ha buscado que haya una conexión estable entre la apófisis larga del yunque y la prótesis, primero para ganar mayor conducción del sonido, y segundo, para evitar que haya mucha vibración entre el yunque y la prótesis, disminuyendo así el riesgo de necrosis.1839 Esto se consigue con una muy maleable que tenga unión firme con el yunque, como la de platino o titanio. El oro y el acero no tienen esa maleabilidad.…”
Section: Discussionunclassified
“…Methodisch kamen dabei Messungen der Übertragungsfunktion mittels Mikrophon in der runden Fensternische [81 ± 83], Elektrocochleographie [84], stroboskopische Untersuchungen [85] sowie dynamische Messungen des intracochleären Druckes zur Anwendung [86]. Erst in den letzten Jahren ist man schrittweise zu einer gezielten Optimierung der mechanischen Eigenschaften von Mittelohrimplantaten und Operationstechniken in Modellrechnungen und Experimenten übergegangen [12, 87 ± 90] Laserinterferometrische Untersuchungen, die am Felsenbeinpräparat die Schwingungsamplituden der Stapesfuûplatte oder des runden Fensters kontrollieren, haben die Messtechnik entscheidend vereinfacht [16, 57, 91 ± 95].…”