2017
DOI: 10.1002/jca.21521
|View full text |Cite
|
Sign up to set email alerts
|

Methods for the detection and serum depletion of porcine galectin‐3

Abstract: Methods have been developed for the detection and depletion of porcine Gal-3. These methods will be used to study the specific effects of Gal-3 depletion via apheresis in porcine models of disease.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…The affinity columns contained LEAF™ purified (BioLegend, San Diego, California) monoclonal antibody M3/38 rat anti‐mouse Gal‐3 monoclonal antibody from hybridoma M3/38.1.2.8 HL.2 (ATCC ® TIB‐166™), covalently bound to hydrated cyanogen‐bromide activated Sepharose 4B (GE Healthcare Life Sciences, Pittsburgh, Pennsylvania) as previously described . For column perfusion, 60 mL matrix volume was packed into a GE XK50/20 column (GE Healthcare Life Sciences, Pittsburgh, Pennsylvania) with a diameter of 50 mm and bed height of ∼30 mm.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The affinity columns contained LEAF™ purified (BioLegend, San Diego, California) monoclonal antibody M3/38 rat anti‐mouse Gal‐3 monoclonal antibody from hybridoma M3/38.1.2.8 HL.2 (ATCC ® TIB‐166™), covalently bound to hydrated cyanogen‐bromide activated Sepharose 4B (GE Healthcare Life Sciences, Pittsburgh, Pennsylvania) as previously described . For column perfusion, 60 mL matrix volume was packed into a GE XK50/20 column (GE Healthcare Life Sciences, Pittsburgh, Pennsylvania) with a diameter of 50 mm and bed height of ∼30 mm.…”
Section: Methodsmentioning
confidence: 99%
“…During apheresis, the inlet flow rate typically ranged between 12–14 mL/minute resulting in a column retention time of ∼4–5 minutes, calculated based on the column having an internal diameter of 50 mm and the Sepharose matrix bed height being approximately 3 cm. To assess the binding efficiency of porcine Gal‐3 to the M3/38 antibody, plasma samples from treated animals were taken pre‐ and post‐passage through the affinity column during apheresis, and Gal‐3 concentrations quantified by sandwich enzyme‐linked immunosorbent assay (ELISA) as previously described . The Gal‐3 specific ELISA has a linear range from 0.3 to 20 ng/mL with a lower limit of detection of 300 pg/mL.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations