2011
DOI: 10.1016/j.chroma.2011.04.006
|View full text |Cite
|
Sign up to set email alerts
|

Multiresidue analytical method for the determination of antimicrobials, preservatives, benzotriazole UV stabilizers, flame retardants and plasticizers in fish using ultra high performance liquid chromatography coupled with tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
59
2
3

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 135 publications
(65 citation statements)
references
References 47 publications
1
59
2
3
Order By: Relevance
“…13,14 It was reported that bioaccumulation factors (BAFs) were found to be as high as 2100 for TCS and 2700 for TCC in algae. 15 Hence, the extensive detection of TCS and TCC has become a public concern as they may affect aquatic organisms such as algae, 16 crustacean 17 and sh.…”
Section: 12mentioning
confidence: 99%
“…13,14 It was reported that bioaccumulation factors (BAFs) were found to be as high as 2100 for TCS and 2700 for TCC in algae. 15 Hence, the extensive detection of TCS and TCC has become a public concern as they may affect aquatic organisms such as algae, 16 crustacean 17 and sh.…”
Section: 12mentioning
confidence: 99%
“…Scientists often used Soxhlet extraction (SE) with different , Johnson-Restrepo et al 2008, Ueno et al 2006, Xian et al 2008, Su et al 2014, Hu et al 2011, Lankova et al 2013, He et al 2013, Zhang et al 2013, Jeong et al 2014, Roosens et al 2008, Roosens et al 2010, Losada et al 2009, McHugh et al 2010. The advantage for this extraction was high recovery values but extraction time was quite long and ranged from 4 to 48 h. Some of the researchers also used classic solvent extraction; nevertheless, recovery values were not always high enough and the consumption of solvents was high (Nyholm et al 2008, Asante et al 2013, Kim et al 2011. Very popular in those kind of matrices was accelerated solvent extraction (ASE, PLE), which can lead to very high recovery values in a short time (Xia et al 2011, Haukas et al 2009, Feng et al 2010, Ilyas et al 2013, ten Dam et al 2012, Gao et al 2014, Sundkvist et al 2010.…”
Section: Introductionmentioning
confidence: 99%
“…In this paper, we focused on two brominated flame retardants (BFRs) that are widely used and produced in high amounts-(TBBPA) and (HBCD) and two organophosphate flame retardants (OPFRs)-EHDP and TPhP. The selection of OPFRs for this study was justified by the fact that these are quite new compounds that have been of researchers' interest in biological samples (Chen et al 2012, Kim et al 2011, Greaves et al 2016). …”
Section: Introductionmentioning
confidence: 99%
“…Estudos recentes relatam a importância do desenvolvimento de novos métodos com o propósito de analisar parabenos, mesmo que em baixas concentrações, em matriz biológica tal como, o peixe e com isso obter dados relevantes que possam relatar níveis de contaminação dos rios e oceanos (JAKIMSKA et al, 2013;SUBEDIA et al,2011;KIM et al, 2011 O detector com arranjo de diodos é um detector amplamente utilizado na cromatografia líquida atualmente, por ser considerado seletivo, uma vez que a substância precisa absorver luz; possuem mecanismos de operação bem estabelecidos, limites de detecção apropriados, são compatíveis com gradientes de eluição, pouco sensíveis a mudanças na temperatura e possuem boa sensibilidade (LANÇAS,2009).…”
Section: Métodos Analíticosunclassified
“…A Tabela (KIM et al, 2011;SUBEDI et al,2011;SUBEDI et al,2011) e coeficiente de determinação compatível com o detector utilizado, como apresentado na Tabela 9.…”
Section: Exatidão E Precisãounclassified