Abstract: BackgroundCurrently, many imaging photoplethysmography (IPPG) researches have reported non-contact measurements of physiological parameters, such as heart rate (HR), respiratory rate (RR), etc. However, it is accepted that only HR measurement has been mature for applications, and other estimations are relatively incapable for reliable applications. Thus, it is worth keeping on persistent studies. Besides, there are some issues commonly involved in these approaches need to be explored further. For example, moti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
24
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(28 citation statements)
references
References 32 publications
1
24
1
Order By: Relevance
“…However, the post-processing of video images is generally time consuming when compared to the majority of contact-based techniques, and infrared video images are usually analyzed after data collection. Other contactless sensors that can simultaneously register f R , face expressions and cardiovascular variables are RGB camera sensors and depth sensors [23,189,190]. When the area of the upper chest is filmed, RGB camera sensors can be used to retrieve respiration-induced body movements from the post-processing of video images [132].…”
Section: Measurement and Computingmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the post-processing of video images is generally time consuming when compared to the majority of contact-based techniques, and infrared video images are usually analyzed after data collection. Other contactless sensors that can simultaneously register f R , face expressions and cardiovascular variables are RGB camera sensors and depth sensors [23,189,190]. When the area of the upper chest is filmed, RGB camera sensors can be used to retrieve respiration-induced body movements from the post-processing of video images [132].…”
Section: Measurement and Computingmentioning
confidence: 99%
“…When the area of the upper chest is filmed, RGB camera sensors can be used to retrieve respiration-induced body movements from the post-processing of video images [132]. Alternatively, if the face of the user is recorded with a camera, RGB camera sensors can be used to extract f R from the modulation of the video PPG signal [189].…”
Section: Measurement and Computingmentioning
confidence: 99%
“…In most of these studies, the estimation of pulse is strongly correlated with the heart rate assessed from finger sensors or electrocardiograms, presenting 1-2% errors. However, while the acquisition process for monitoring the vascular pulse has been simplified, further challenges related to motion artifacts such as respiratory and head movements still require to be taken into consideration [51], [54], [.It has been recently suggested [58] that using two regions of interest could be a solution to evaluate dynamic heart rate by detecting other physiological signs (eg. eye blinking, yawning).…”
Section: A Monitoring Of Vascular Pulsementioning
confidence: 99%
“…Due to the mentioned drawbacks within the existing measurement processes and ever increasing number of possible medical, research and commercial fields of applications, researchers worldwide are exploring the possibilities of experimental non-contact measuring techniques. Several promising novel methods are emerging with encouraging results [ 21 , 22 , 23 , 24 ].…”
Section: Introductionmentioning