Novel Optical Biosensor Based on a Nano-Gold Coated by Schiff Base Doped in Sol/Gel Matrix for Sensitive Screening of Oncomarker CA-125

Abstract: The urge for sensitive, facile, minimally invasive, and fast detection method of CA-125, a significant and crucial biomarker in ovarian malignancy, is currently substantial. This paper describes the detailed construction and characterization of a newly designed optical nano-biosensor to detect CA-125 accurately and sensitively. The fabricated sensor consists of a nano-gold thin film doped into a matrix of sol–gel, exhibiting a centered fluorescence band at 423 nm when excited at 340 nm. The quantification of C… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(7 citation statements)
references
References 70 publications
0
7
0
Order By: Relevance
“…The chemosensors based on the fluorescence method have the characteristics of a short response time, selectivity, and a wide detection range. Its basic principle is the specific interaction between the biomolecules on the sensor and the object to be analyzed [4,[150][151][152][153][154][155][156]. The light signal formed by absorption or emission band changes resulting from chemical interactions is easily detected by fluorescent molecules, with the light signal correlated with the concentration of the analyte [157][158][159][160][161][162][163][164][165].…”
Section: Optical Sensormentioning
confidence: 99%
“…The chemosensors based on the fluorescence method have the characteristics of a short response time, selectivity, and a wide detection range. Its basic principle is the specific interaction between the biomolecules on the sensor and the object to be analyzed [4,[150][151][152][153][154][155][156]. The light signal formed by absorption or emission band changes resulting from chemical interactions is easily detected by fluorescent molecules, with the light signal correlated with the concentration of the analyte [157][158][159][160][161][162][163][164][165].…”
Section: Optical Sensormentioning
confidence: 99%
“…Within cells, Schiff base compounds have been used as biosensors for H 2 O 2 , glucose, and Oncomarker CA-125 [87]. Evaluation of the sensitivity and specificity of the gold Schiff base complex-doped sol gel nano optical sensor for the detection of CA-125 in ovarian cancer patient samples was performed and compared to results obtained from samples taken from healthy women serving as a control group [88]. Sheta M. Sheta et al created an ultrasensitive method of detecting human creatinine using a cerium(III)-isatin Schiff base complex as an optical sensor [89].…”
Section: Bio-sensing Applicationsmentioning
confidence: 99%
“…A linear response of the sensor in the concentration range of 2–127 U/mL with a LOD of 1.25 U/mL of CA125 was observed. The sensor showed the ability to discriminate between diseased people and the healthy population [ 140 ]. Omer et al exploited the optical properties of carbon quantum dots (CQDs) for the biosensing of CA125.…”
Section: Biomarkers and Their Biosensorsmentioning
confidence: 99%