2004
DOI: 10.1016/j.aca.2004.08.014
|View full text |Cite
|
Sign up to set email alerts
|

On-line conversion and determination of artemisinin and its kinetic parameters using orthogonal design by coupling of flow injection with capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2005
2005
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 17 publications
0
10
0
Order By: Relevance
“…An earlier method involved conversion of (1) to a UV absorbing compound Q260 to facilitate its detection [17][18][19]. The disadvantage of this method is that the derivatization procedure from (1) to Q260 is time consuming and introduces significant experimental errors [20]. Other methods include gas chromatography with flame ionization (GC-FID) [21,22], supercritical fluid chromatography with ELSD [23], FID [24] and MS [25] detection.…”
Section: Introductionmentioning
confidence: 99%
“…An earlier method involved conversion of (1) to a UV absorbing compound Q260 to facilitate its detection [17][18][19]. The disadvantage of this method is that the derivatization procedure from (1) to Q260 is time consuming and introduces significant experimental errors [20]. Other methods include gas chromatography with flame ionization (GC-FID) [21,22], supercritical fluid chromatography with ELSD [23], FID [24] and MS [25] detection.…”
Section: Introductionmentioning
confidence: 99%
“…14,15) As solubilizing agents, TW-80 (in 10% (w/v) solution), PG and TC were all examined at 4 levels. The essential oil, extracted from 4.5 kg Radix Bupleuri, was divided into 16 parts, and according to the L 16 (4 5 ) orthogonal table (Table 1), TW-80, PG and/or TC were added to each tube before water was filled until the final volume was 18.75 ml (1 ml solution containing oil from 15 g Bupleuri), followed by stirring for 5 min.…”
mentioning
confidence: 99%
“…Therefore, efficient automation of these operations is highly desired for future development. A CE coupled with FI method for the determination of artemisinin and its relevant kinetic parameters by on-line treatment with alkali has been developed by Cheng et al [25]. Orthogonal experimental design has been utilized to optimize experimental factors that affect the analysis of artemisinin.…”
Section: Conventional Fi-ce Systemmentioning
confidence: 99%