2004
DOI: 10.1016/j.polymertesting.2004.05.001
|View full text |Cite
|
Sign up to set email alerts
|

On-line monitoring of the residence time distribution along a kneading block of a twin-screw extruder

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
29
0
1

Year Published

2007
2007
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(32 citation statements)
references
References 25 publications
2
29
0
1
Order By: Relevance
“…O parâmetro E(t) representa a variação da concentração de marcador na saída da extrusora e F(t) representa a quantidade acumulada de traçador na saída após um dado intervalo de tempo [12][13][14]. Essas funções são definidas como:…”
Section: Modelo Teóricounclassified
“…O parâmetro E(t) representa a variação da concentração de marcador na saída da extrusora e F(t) representa a quantidade acumulada de traçador na saída após um dado intervalo de tempo [12][13][14]. Essas funções são definidas como:…”
Section: Modelo Teóricounclassified
“…The RTD density function, E(t), shows the variation of the tracer concentration at the exit and is given by the following equation (Carneiro et al, 2004):…”
Section: Evaluations Of the Mixing Efficiencymentioning
confidence: 99%
“…Carneiro et al [73] determined the RTD along a kneading block via in-line monitoring of the light emission of a fluorescent tracer (perylene) in a slit die attached to a singlescrew extruder and at several locations along a corotating twin-screw extruder. RTD measurements are often used to monitor and control process attributes such as consistency, extent of polymer degradation and degree of mixing.…”
Section: Fluorescence Spectroscopymentioning
confidence: 99%
“…Solutions to accommodate the optical probe: (a) slit die used for measurements in a single screw extruder; (b) modified sampling device for partial measurements in a twin-screw extruder; and (c) device for partial measurement along a transparent barrel. [73] Dielectric spectroscopy Perusich and McBrearty [77] applied dielectric spectroscopy to make composition measurements of the comonomer concentration along polymer chains. Dielectric spectroscopy imposes an electric field across the flowing polymer and measures the resultant alternating current produced from the movement and energy associated with dipole orientation and ionic conduction.…”
Section: Terahertz Spectroscopymentioning
confidence: 99%