2006
DOI: 10.1116/1.2348728
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of a Cl2–H2 inductively coupled plasma etching process adapted to nonthermalized InP wafers for the realization of deep ridge heterostructures

Abstract: Inductively coupled plasma etching using Cl2–H2 chemistry with no additive gas (CH4, Ar, or N2) is studied to realize deep (>5μm) ridges with smooth and vertical sidewalls. The process is optimized for nonthermalized InP wafers to avoid the use of thermal grease. Cleaning of the rear side of the wafer after etching is avoided, which is suitable for an industrial process or for critical subsequent steps such as epitaxial regrowth. The influence of the Cl2∕H2 ratio on the etching mechanism is investigated… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
40
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 35 publications
(41 citation statements)
references
References 16 publications
1
40
0
Order By: Relevance
“…12 that Cl 2 has the dominant impact upon the stoichiometry of the InP etched surface. In this study, the two main conditions that were chosen were that of a pure Cl 2 plasma at 0.5 mTorr pressure with a Cl 2 flow-rate of 20 sccm (the conditions used in the SI500 reactor 2,10,11 ), and that of a Cl 2 /Ar gas mixture at 4 mTorr pressure with Cl 2 /Ar flow rates of 17.5/70 sccm (as used in the Centura etch platform 12 ). The DC bias was varied between À20 and À140 V. Finally, the electrode temperature was varied between 130-240 C. Affixing the InP samples or leaving the samples unaffixed to the c-Si wafer strongly influenced the actual sample temperature, as will be discussed below.…”
Section: Experimental Conditions a General Etching Conditionsmentioning
confidence: 99%
See 3 more Smart Citations
“…12 that Cl 2 has the dominant impact upon the stoichiometry of the InP etched surface. In this study, the two main conditions that were chosen were that of a pure Cl 2 plasma at 0.5 mTorr pressure with a Cl 2 flow-rate of 20 sccm (the conditions used in the SI500 reactor 2,10,11 ), and that of a Cl 2 /Ar gas mixture at 4 mTorr pressure with Cl 2 /Ar flow rates of 17.5/70 sccm (as used in the Centura etch platform 12 ). The DC bias was varied between À20 and À140 V. Finally, the electrode temperature was varied between 130-240 C. Affixing the InP samples or leaving the samples unaffixed to the c-Si wafer strongly influenced the actual sample temperature, as will be discussed below.…”
Section: Experimental Conditions a General Etching Conditionsmentioning
confidence: 99%
“…For purposes of comparison, the parameters were chosen to be equivalent to those used for InP etching in the Centura 300 etch platform 12 and to those previously optimized in the SI500 etch system for anisotropic etching of InP-based waveguides using a Cl 2 -H 2 chemistry. 2,10,11 The ICP power was fixed at 800 W, the Cl 2 partial pressure was kept in the 0.5-1 mTorr range, and the feed gas was either pure Cl 2 or a Cl 2 /Ar mixture. It was shown in the in-situ XPS study of Ref.…”
Section: Experimental Conditions a General Etching Conditionsmentioning
confidence: 99%
See 2 more Smart Citations
“…N2 gas was added to serve as the sidewall passivation [24,25]. Several other gas combinations can also be used to selectively etch the InGaAs over Si3N4 [26][27][28]. The gas flow, etching power, chamber pressure, and sample temperature have to be optimized to achieve high etching selectivity over Si3N4, smooth etched surface, high etch rate, and minimum sidewall undercutting etching to achieve ~50% grating duty cycle.…”
Section: Device Fabricationmentioning
confidence: 99%