2022
DOI: 10.1109/tia.2022.3152973
|View full text |Cite
|
Sign up to set email alerts
|

Performance Evaluation of a Dual-Input Hybrid Step-Up DC–DC Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 31 publications
0
8
0
Order By: Relevance
“…This means that the power efficiency could improve on using soft-switching topologies under heavy-load conditions. Table V presents a comparative analysis of the dual-input hybrid step-up converter [29], the MI converters [30], [31], the conventional MI Ćuk converter [20], and the proposed converter. As shown in Table V, the current stress of switches in the proposed converter is lower than the MI converter in [20], [29], [30], and [31].…”
Section: ) Operation Of the Full-scale Proposed Convertermentioning
confidence: 99%
See 2 more Smart Citations
“…This means that the power efficiency could improve on using soft-switching topologies under heavy-load conditions. Table V presents a comparative analysis of the dual-input hybrid step-up converter [29], the MI converters [30], [31], the conventional MI Ćuk converter [20], and the proposed converter. As shown in Table V, the current stress of switches in the proposed converter is lower than the MI converter in [20], [29], [30], and [31].…”
Section: ) Operation Of the Full-scale Proposed Convertermentioning
confidence: 99%
“…Table V presents a comparative analysis of the dual-input hybrid step-up converter [29], the MI converters [30], [31], the conventional MI Ćuk converter [20], and the proposed converter. As shown in Table V, the current stress of switches in the proposed converter is lower than the MI converter in [20], [29], [30], and [31]. This is because the proposed converter adopts the current sharing circuit to reduce the current stress of each switch.…”
Section: ) Operation Of the Full-scale Proposed Convertermentioning
confidence: 99%
See 1 more Smart Citation
“…This can be solved by incorporating multi-port converters. Reference [28] Describes a non-isolated high step-up multi-port converter and its performance evaluation using a variety of parameters. References [29] and [30] evaluate the MPPT of a solar PV converter under partial shading conditions.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, it is operated with a time‐sharing scheme, which results in the underutilization of sources. The switch inductor technique is used in literature 8 for step‐up output voltage in integrating hybrid energy sources. However, it is only used in boost mode.…”
Section: Introductionmentioning
confidence: 99%