2022
DOI: 10.3390/children9111757
|View full text |Cite
|
Sign up to set email alerts
|

Quality of Ventilations during Infant Resuscitation: A Simulation Study Comparing Endotracheal Tube with Face Mask

Abstract: Background: There are few studies that analyze ventilation volume and pressure during CPR carried out on infants. The aim of this study was to evaluate the quality of the ventilations administered using a self-inflating bag with an endotracheal tube and a face mask in manikins. Methods: a quasi-experimental simulation study with a randomized case crossover design [endotracheal tube (ET) vs. face mask (FM)] was performed. Sixty participants who were previously trained nursing students participated in the study.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 20 publications
0
2
0
Order By: Relevance
“…Nevertheless, ventilations are not necessarily effective, and their volume can markedly vary from one ventilation attempt to another. A recent simulation study by Santos-Folgar et al showed that insufflations delivered using BVM devices failed to reach the alveoli 14% of the time and that the volume of 72% of these ventilations was considered insufficient [ 25 ]. In the present study, ventilations were applied by professional prehospital providers, and the proportion of ventilations below the 30 mL target were very low (less than 5%).…”
Section: Discussionmentioning
confidence: 99%
“…Nevertheless, ventilations are not necessarily effective, and their volume can markedly vary from one ventilation attempt to another. A recent simulation study by Santos-Folgar et al showed that insufflations delivered using BVM devices failed to reach the alveoli 14% of the time and that the volume of 72% of these ventilations was considered insufficient [ 25 ]. In the present study, ventilations were applied by professional prehospital providers, and the proportion of ventilations below the 30 mL target were very low (less than 5%).…”
Section: Discussionmentioning
confidence: 99%
“…These devices present several drawbacks. Difficulties in ventilating with a BVM are not uncommon [10], with a significant incidence of excessive or insufficient (in terms of volume and/or pressure) ventilations [11]. Air leaks are frequently encountered when using basic airway management devices and are associated with lower and often unsatisfactory tidal volumes [12].…”
Section: Introduction 1backgroundmentioning
confidence: 99%