1998
DOI: 10.1259/bjr.71.849.10195011
|View full text |Cite
|
Sign up to set email alerts
|

Radiation exposure to medical staff in interventional and cardiac radiology.

Abstract: The aim of this work has been to determine typical occupational dose levels in interventional radiology and cardiology installations and to relate doses to patient and occupational dosimetry through the dose-area product. An experimental correlation between environmental dosimetric records and dose-area products in the centres studied was established. The study covered a sample of 83 procedures performed by 10 specialists in six laboratories. The radiologists and cardiologists monitored wore nine thermolumines… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
94
2
2

Year Published

2004
2004
2016
2016

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 313 publications
(100 citation statements)
references
References 20 publications
2
94
2
2
Order By: Relevance
“…Therefore, radiation safety is essential in the quality administration of cardiac catheterization laboratories [1,5]. Understanding the risks inherent to radiation exposure and being conscious of the means to minimize these hazards are mandatory for every interventionist.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, radiation safety is essential in the quality administration of cardiac catheterization laboratories [1,5]. Understanding the risks inherent to radiation exposure and being conscious of the means to minimize these hazards are mandatory for every interventionist.…”
Section: Discussionmentioning
confidence: 99%
“…The lowest doses for coronary angiographies (CAs) were found in a hospital centre (3) with very strict radiation protection policy (low exposure rate fluoroscopy modes, use of spectral filters, low frame rate, proper use of protective screens, protective collar, lead aprons and curtain shields). The use of a protective barrier can reduce staff doses by a factor of 2, whereas the use of a ceiling mounted screen by a factor of 3 (4) .…”
Section: Use Of Extremity Dosemeters In Interventional Proceduresmentioning
confidence: 99%
“…For vascular radiology procedures, finger doses up to 840 mSv per procedure (4) have been reported. Without protective devices, the hand doses in angiographies vary from 120 to 710 mSv per procedure.…”
Section: Use Of Extremity Dosemeters In Interventional Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…This article presents data recorded by ALARA OD-type of AEPDs (10 -12) worn as additional personal dosemeters (4,5,9) by four medical specialists as shown in Figure 1. AEPDs were strapped on the protective apron, on the left side at the chest level (9,10) .…”
Section: Resultsmentioning
confidence: 99%