Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
66
1
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 78 publications
(73 citation statements)
references
References 20 publications
5
66
1
1
Order By: Relevance
“…[15][16][17] Although the selected cases in the present article were challenging by design, as shown in Table 3, we found reasonable agreement with other published data reported on radiation therapy delivery to multiple targets. 1,2,15,16,18 As seen in Table 3, the literature results generally fell within or very close to the 95% prediction band based on the model presented in Figure 3. Of particular note were the results by Ma et al 15 and McDonald et al, 16 which indicated for specific cases a volume of normal brain receiving 60% and 50% of the prescription dose higher than the upper limit of our model's 95% prediction band.…”
Section: Discussionsupporting
confidence: 67%
See 1 more Smart Citation
“…[15][16][17] Although the selected cases in the present article were challenging by design, as shown in Table 3, we found reasonable agreement with other published data reported on radiation therapy delivery to multiple targets. 1,2,15,16,18 As seen in Table 3, the literature results generally fell within or very close to the 95% prediction band based on the model presented in Figure 3. Of particular note were the results by Ma et al 15 and McDonald et al, 16 which indicated for specific cases a volume of normal brain receiving 60% and 50% of the prescription dose higher than the upper limit of our model's 95% prediction band.…”
Section: Discussionsupporting
confidence: 67%
“…Huang et al 18 Table 3, the TPS itself likely plays an influential role in determining brain dose. In the present study, we observed that the TPS optimization engine produced undesirable segments for multiple targets (Figure 4).…”
Section: Discussionmentioning
confidence: 99%
“…The multileaf collimators' (MLC) leaf resolution is also improving, with 2.5 mm leaf widths at the isocenter, in order to improve the dose conformality to the target (12) . Treatment delivery methods have advanced to further improve conformality to complex geometric targets, while limiting dose to critical organs, such as dynamic conformal arc (DCA), Intensity Modulated Radiation Therapy (IMRT), and Volumetric Modulated Arc Therapy (VMAT) 13 , 14 , 15 , 16 . In the era of image guidance, numerous methods have been developed for stereotactic treatment delivery, including optical surface monitoring, in‐room CT, stereoscopic X‐ray imaging, ultrasound, and cone‐beam computed tomography (CBCT) 17 , 18 , 19 , 20 .…”
Section: Introductionmentioning
confidence: 99%
“…The most recent commercial implementation (HyperArc, Varian Medical Systems) offers refinements in terms of planning automation and collision prevention 10. Alternatively, Huang et al11 proposed a concept of single isocenter dynamic conformal arcs (SIDCA), whereby each lesion is treated by a dedicated group of dynamic conformal arcs but all groups share the same isocenter positioned between all targets. This allows for more efficient dynamic arc treatment, as only one isocenter setup is necessary, and the couch angles and arc directions can be optimized for fastest delivery.…”
Section: Introductionmentioning
confidence: 99%