2014
DOI: 10.1364/ao.53.000h76
|View full text |Cite
|
Sign up to set email alerts
|

Research of accommodative microfluctuations caused by visual fatigue based on liquid crystal and laser displays

Abstract: Different levels of visual fatigue in the human eye depend on different color-formation methods and image quality. This paper uses the high-frequency component of the spectral power of accommodative microfluctuations as a major objective indicator for analyzing the effects of visual fatigue based on various displays, such as color-formation displays and 3D displays. Also, a questionnaire is used as a subjective indicator. The results are that 3D videos cause greater visual fatigue than 2D videos (p<0.001), the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
2

Year Published

2015
2015
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(22 citation statements)
references
References 45 publications
(55 reference statements)
0
20
2
Order By: Relevance
“…Several studies have explored the question of whether the magnitudes of the MFs or their components change as a result of asthenopia following extensive periods of near work . It appears that any increase in HFC may be helpful in identifying individuals with asthenopia, or display media with unsatisfactory characteristics.…”
Section: Later Workmentioning
confidence: 99%
“…Several studies have explored the question of whether the magnitudes of the MFs or their components change as a result of asthenopia following extensive periods of near work . It appears that any increase in HFC may be helpful in identifying individuals with asthenopia, or display media with unsatisfactory characteristics.…”
Section: Later Workmentioning
confidence: 99%
“…The symptoms induced by viewing stereoscopic images, if any, are mostly within the range of severe discomfort or visual fatigue [1]. The assessment method of visual fatigue is becoming a hot topic in the field of display quality evaluation [2], to solve such problems, it is necessary to find a suitable indicator for evaluating the effect of stereoscopic displays on human vision. 3D visual fatigue has already been studied using questionnaires, CFF and ACC in [3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…The findings suggest that the aspheric design (Digital Zone Optics) of the comfilcon A, Biofinity® Energys lens reduced the accommodative load on the eyes of subjects to a greater extent than did the spherical design of the Biofinity® sphere. Given the association between AMF and asthenopia -AMF is sometimes used as an objective measure of asthenopia -, Biofinity® Energys would be expected to reduce subjective symptoms of eye strain [17][18][19]. The only difference between the two lens types used in this study was their front-surface optical designs, showing that the aspheric design of Biofinity® Energys reduced the accommodative load presented to the ciliary muscles by the reading task.…”
Section: Discussionmentioning
confidence: 99%
“…A number of studies have used AMF as an objective measure of eye strain [17][18][19], including studies that investigated AMF associated with vision correction. In a randomized cross-over study, Kajita et al compared AMF between wear of 2-weekly replacement Menicon DUO and ACUVUE® 2 (etafilcon A) contact lenses [20].…”
Section: Discussionmentioning
confidence: 99%