2016
DOI: 10.5120/ijca2016909882
|View full text |Cite
|
Sign up to set email alerts
|

Smart Real-Time Healthcare Monitoring and Tracking System using GSM/GPS Technologies

Abstract: Recently, remote monitoring systems have evolved to respond for particular needs in healthcare sector, which is an essential pillar in the modern concept of smart city, we propose a smart system to monitor patient current health conditions, as a smart healthcare system based on the widely spread available technologies; namely, GSM and GPS. Statistics shows that hypertensive heart disease and blood pressure are risk factors for high death rate to decrease it a preventive measures should be applied providing a r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(8 citation statements)
references
References 5 publications
0
6
0
Order By: Relevance
“…The nearest hospital received a distress notification from the proposed device for patient, it contains the patient's name, heart rate and time of heart attack as shown in figure (16). To confirm the response to the distress request, a notification page is entered that contains the patient's personal , vital information, as well as his current location and navigation through directions on Google maps, medical file is also created for the patient in this hospital received the distress request as shown in figure (17,18). If the nearest hospital is not ready to receive the patient, send notification is automatically to the next hospital in terms of the closest distance as shown in figure (19).…”
Section: Chapter 4: Applications and Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The nearest hospital received a distress notification from the proposed device for patient, it contains the patient's name, heart rate and time of heart attack as shown in figure (16). To confirm the response to the distress request, a notification page is entered that contains the patient's personal , vital information, as well as his current location and navigation through directions on Google maps, medical file is also created for the patient in this hospital received the distress request as shown in figure (17,18). If the nearest hospital is not ready to receive the patient, send notification is automatically to the next hospital in terms of the closest distance as shown in figure (19).…”
Section: Chapter 4: Applications and Resultsmentioning
confidence: 99%
“…The data will be acquired using the sensors and compared to a specified limit. The study concentrates on heart rate, body temperature, and therefore in the event of an emergency, an SMS will be sent to the doctors mobile phone containing measured values and position [17].…”
Section: Related Workmentioning
confidence: 99%
“…The life span of electronic components, which includes the bio-sensors, microcontroller, GPS and GSM, refers to the time of the first transmission until those components lost their working capability in the FDD, specially GPS and GSM [45,46,47]. In this study our proposed device turns off the GPS and GSM modules until it detects the patient’s fall, thus reducing FDD current consumption.…”
Section: Resultsmentioning
confidence: 99%
“…Some previous work has adopted GSM for the wireless data technology [45,46,47] in WBSN applications because of the long transmission distances and the need to be used in both indoor and outdoor environments. This work adopted a small GSM module based on SIM800L.…”
Section: System Architecturementioning
confidence: 99%
“…Highlights of this sensor are as per the following: Calibrated specifically in Degree Celsius (Centigrade), Linear at 10.0 mV/°C scale factor, it is capable of measuring temperature at 0.5°C precision at 25°C, Its range of measuring is -55°C to a 150°C, Its advantage is that this sensor is suitable for remote control applications, and is available at low cost because of waferlevel trimming, It can work with a voltage from 4 to 30 volts, it consumes less than 60 mA current deplete, it do not get selfwarming, 0.08°C impart air, Its non-linearity is just 0.25°C regular, Low impedance yield, 0.1ωfor 1 mA stack. [5] Pulse Sensor…”
Section: Block Diagram Lm35mentioning
confidence: 99%